AC90 Copper Cable Dub Liab 2C Rau Cable Trough Wiring 600V

AC90 Copper Cable Dub Liab 2C Rau Cable Trough Wiring 600V
Details:
· Tus neeg xyuas pib: Khoom muag tooj liab, ASTM B3
· Rwb thaiv tsev: Hla- txuas Polyethylene (XLPE) CSA Hom XL 90℃qhuav / ntub 600V Halogen-Dawb
· Xim Code: Dub, Liab
· Bonding Conductor: Khoom ASTM B3 Mos liab qab tooj liab
· Armour: Aluminium (AIA) lossis Galvanized Steel (SIA) Interlock Armor
· Kev ntsuas hluav taws xob: 600V
Send Inquiry
Download
Kev piav qhia
Technical Parameters
Daim ntawv pov thawj

Dongguan Greater Wire & Cable Co., Ltd. yog ib qho ntawm cov ua lag luam thiab cov neeg muag khoom ntawm ac90 tooj liab cable dub liab 2c rau cable trough wiring 600v hauv Suav teb, kuj txhawb kev pabcuam. Thov so assured mus yuav luv nqi ac90 tooj liab cable dub liab 2c rau cable trough wiring 600v ua nyob rau hauv Suav teb nov los ntawm peb lub hoobkas. Yog tias koj muaj lus nug txog cov qauv dawb, thov koj xa email rau peb.

 

aluminum armour AC90 wire

PRODUCT REAL SHOT

 

two conductor black red AC90 cable
two conductor black red AC90 wire
black red 600V AC90 cable

black red 600V AC90 wire

Flexible armored tsev hlau rau kev koom ua ke sab hauv routing systems
AC90 cable trough wiringyog 600V tooj liab -conductor AC90 tov tsim rau cable trough wiring. Nws cov qauv sab hauv suav nrog RW90 XLPE insulated Circuit Court conductors, tus neeg xyuas pib sib txuas thiab daim ntawv qhwv hauv qab hloov pauv hloov pauv ntawm cov khoom siv txhuas. Cov Dub/Liab ob-configuration configuration muab installers pom meej qhov txawv ntawm Circuit Court cores thiab txhawb cov xaiv sab hauv tsev ceg-circuit layouts. Rau cov neeg yuav khoom ntsuas AC90 tooj liab cable, GERITEL WIRE muaj lub Hoobkas tsim, kev cai cable qhia, xaiv ntim thiab scalable mov rau qhov project lossis distributor xav tau. Cov kab hluav taws xob yog qhov zoo tshaj plaws rau cov ntawv thov hauv tsev qhuav hauv qhov chaw uas muaj kev tiv thaiv kev tiv thaiv, kev txhim kho yooj yim thiab zoo ib yam B2B cov khoom tseem ceeb.
PRODUCT SPECIFICATIONS

 

AC90 product certification cable

APPLICATIONS

 

Tsim, kuaj thiab ntawv pov thawj hauv Canada, GERITEL WIRE AC90 armored tsev hlau yog ntsuas FT4-ST1 rau -40℃rau 90 degree. Engineered tshwj xeeb rau kev xav tau ib puag ncig, superior flammability thiab pa taws emission kev ua tau zoo.

Tsim los rau ib leeg -Theem cua sov Installations.

Siv rau hauv qhov cua, tsis yog - qhov cua thiab ntaiv - hom cable tais.

Rau qhov chaw qhuav, hauv qab nthab saum huab cua- tuav cov plenums, nthuav tawm lossis zais thaiv thiab kev pabcuam nkag rau saum av.

SPECIFICATIONS
Tus coj Khoom siv tooj liab, ASTM B3
Rwb thaiv tsev Hla -txuas polyethylene (XLPE) CSA Hom XL 90℃qhuav / ntub 600V Halogen-Dawb
Xim Code Dub, Liab
Bonding Conductor Khoom ASTM B3 Mos liab qab tooj liab
Armor Aluminium (AIA) lossis Galvanized Steel (SIA) Interlock Armor
Specifications thiab kev ua raws cai

CSA C22.2 No. 51, Armored Cables (Hom AC90)

CSA C22.2 Tsis yog. 38 Thermoset-cov xov hlau thiab cov hlua hluav taws xob (Hom RW90)

CSA C22.2 No. 2556 FT4-ST1/UL 1685 Vertical-Tray Flame Test

IEEE 383 & 1202, ICEA T-30-520 (70,000 BTU/hr) Vertical Flame Test ntsuas

-40℃Txias Khoov thiab -40℃Txias cuam tshuam

Txwv tsis pub haus luam yeeb thiab halogen dawb

AC90 & ISO-AC90 600V CSA FT4-ST1 LSZH

 

AC 90

Hwj chim

Tus coj

Hauv av

Tus coj

Rwb thaiv tsev

Thickness

Armor

O.D

Kab

Qhov hnyav

Max rub

Kev ntxhov siab

Min Khoov Radius Kev txaus siab
Suav AWG AWG hauv mm hauv mm lbs/Mft kg/km lbs kg hauv mm A
2 14 14 0.030 0.76 0.430 10.9 81 120 66 30 6.0 151 25
2 12 14 0.030 0.76 0.454 11.5 99 148 104 47 6.4 164 30
2 10 12 0.030 0.76 0.512 13.0 138 206 166 75 6.9 174 40
3 14 14 0.030 0.76 0.445 11.3 105 156 99 45 6.2 158 25
3 12 14 0.030 0.76 0.490 12.4 130 193 157 71 6.9 174 30
3 10 12 0.030 0.76 0.535 13.6 182 271 249 113 7.5 190 40
3 8/7 10 0.045 1.14 0.714 18.1 309 460 418 190 10.0 254 55
3 6/7 8/7 0.045 1.14 0.770 19.6 417 621 702 318 10.8 274 75
3 4/7 8/7 0.045 1.14 0.940 23.9 601 894 1193 541 13.2 334 95
3 3/7 6/7 0.045 1.14 0.990 25.1 721 1073 1622 736 13.9 352 115
3 2/7 6/7 0.045 1.14 1.040 26.4 891 1326 1922 872 14.6 370 130
4 14 14 0.030 0.76 0.490 12.4 130 193 131 60 6.9 174 20
4 12 14 0.030 0.76 0.535 13.6 166 247 209 95 7.5 190 24
4 10 12 0.030 0.76 0.630 16.0 232 345 332 150 8.8 224 32

 

ISO -AC90

Tus coj

Suav

Hwj chim

Tus coj

Hauv av

Tus coj

Hauv av

Tus coj

Rwb thaiv tsev

Thickness

Armor

O.D

Kab

Qhov hnyav

Max rub

Kev ntxhov siab

Min Khoov Radius Kev txaus siab
AWG AWG AWG hauv mm hauv mm lbs/Mft kg/km lbs kg hauv mm A
2 14 14 14 0.030 0.76 0.440 11.2 105 156 66 30 6.2 157 25
2 12 12 14 0.030 0.76 0.485 12.3 138 206 104 47 6.8 173 30
2 10 10 12 0.030 0.76 0.533 13.5 186 277 166 75 7.5 190 40
3 12 12 14 0.030 0.76 0.535 13.6 165 245 157 71 7.5 190 24
3 10 10 12 0.030 0.76 0.591 15.0 232 346 249 113 8.3 210 32
CERTIFICATIONS

 

AC90 product certification wire

Ntim

 

AC90 cable for modular office wiring

Yob

AC90 CSA compliance

Yas Reel

AC90 cable for modular school wiring

Me meNtoo Reel

APPLICATION

 

AC90 wire for modular school wiring
Chav tsev/Residential Building Electrical Distribution
AC90 black red CSA compliance
Commercial Building Electrical Distribution
AC90 copper CSA compliance
Industrial Factory Fais Fab Kev faib tawm
CAS

 

AC90 cable for prefab house wiring

Calgary Alberta Multi Storey Apartment Kev Txhim Kho Kev Txhim Kho

AC90 2 conductor CSA compliance

Toronto Ontario Detached House Hauv qab Vaj Huam Sib Luag Hloov Kho

AC90 cUL certification

Vancouver British Columbia Downtown Office Renovation

Vim li cas thiaj xaiv peb

 

30Xyoo ntawm kev paub
hauv ib qho - nres kev pabcuam

Dongguan Greater Wire & Cable Co., Ltd. yog tus kws tshaj lij engineering- qib cable chaw tsim khoom hauv Suav teb, muab cov ntawv pov thawj hluav taws xob cable daws teeb meem rau lub tsev, kev lag luam, tsuas, hluav taws xob, thiab kev tsim kho vaj tse thoob ntiaj teb.

Nrog rau 30,000 m² Hoobkas, 30 cov kab ntau lawm, cov kws paub txog engineers, thiab pab pawg tswj xyuas nruj, peb muab cov khoom lag luam txhim khu kev qha, traceable, thiab ua raws cov khoom siv cable rau kev siv engineering thoob ntiaj teb. Peb cov khoom tau txais kev txhawb nqa los ntawm cov ntawv pov thawj suav nrog SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, thiab ISO.

Peb tau cog lus rau kev nyab xeeb, kev ua tau zoo, pob tshab, thiab kev sib koom ua ke ntev -. Los ntawm kev tshuaj xyuas cov khoom siv raw mus rau kev kuaj cov khoom tiav, txhua batch yog ua tib zoo tswj xyuas kom ruaj khov kev ua tau zoo thiab siv tau qhov project.

Greater Cable - Certified Quality. Kev ntseeg tau. Engineering tus nqi.

AC90 black red cUL certification
 
15K
Kev Ua Haujlwm tiav
150+
cov neeg ua haujlwm tshaj lij
15K
zoo siab cov neeg siv khoom
92+
khoom plig & certifacates
COV TSWV YIM

 

AC90 2 conductor cUL certification
 
AC90 copper cUL certification
 
AC90 cable for manufactured home interior wiring
 
AC90 wire for manufactured home interior wiring
 
AC90 600V rating
 
AC90 black red 600V rating
 
GLOBAL CERTIFICATIONS

 

AC90 copper 600V rating

COV PHOOJ YWG
 

AC90 2 conductor 600V rating

INTERNATIONL TRANSPORTATION

 

01

Hiav txwv Freight

Peb muab cov kev daws teeb meem hauv hiav txwv txhim khu kev qha rau loj - ntim xaj. Koj cov khoom tau ntim khoom ruaj ntseg thiab xa mus rau hauv cov thawv ntim khoom, xyuas kom tus nqi - xa mus rau cov chaw nres nkoj thoob ntiaj teb.

02

Cua Freight

Rau kev xa khoom sai, peb cov kev pabcuam huab cua ua kom koj cov khoom mus txog thoob ntiaj teb cov chaw sai sai, nrog kev ceev faj thiab taug qab tag nrho ntawm txoj kev.

03

International Express

Xav tau kev thauj mus los sai? Peb cov kev pabcuam nthuav qhia thoob ntiaj teb xa cov xaj me me mus rau nruab nrab kom tau txais txiaj ntsig zoo, muab lub qhov rooj - rau - qhov rooj pabcuam nrog - lub sijhawm taug qab kom muaj kev thaj yeeb nyab xeeb.

AC90 90C temperature rating
COOPERATIVE PARTNER

 

Peb tab tom nrhiav kev sib koom tes los nthuav peb txoj kev lag luam.

AC90 building wire cUL CSA certified
AC90 copper 90C temperature rating
AC90 black red 90C temperature rating
AC90 cable for container house interior wiring
AC90 electrical cable cUL CSA certified
AC90 2 conductor cable cUL CSA certified
AC90 2 conductor 90C temperature rating
AC90 FT4 flame performance
AC90 black red FT4 flame performance
AC90 copper cable 600V
Yuav koom tes nrog peb li cas?

Tsuas qhia koj cov kev xav tau, tau txais peb cov kev daws teeb meem, paub meej cov qauv, thiab txaus siab rau kev tsim khoom sai, txhim khu kev qha thiab xa khoom thoob ntiaj teb - ua haujlwm nrog peb yog qhov yooj yim.

Peb qhov chaw nyob

Tsev 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Suav teb

Xov tooj

+86 136 6257 9592

+86 135 1078 4550

E -mail

manager01@greaterwire.com

AC90 copper FT4 flame performance
FAQ

 

Koj puas tuaj yeem muab cov kev cai ntim khoom?
Yog lawm. AC90 cable ntim tuaj yeem ua raws li cov lus qhia, coil, pallet thiab daim ntawv lo raws li qhov project kom muaj nuj nqis thiab logistics xav tau.
GERITEL WIRE puas tuaj yeem txhawb nqa qhov kev txiav txim?
Yog lawm. Raws li AC90 qhov project cable tus tswv lag luam Canada tus khub, GERITEL WIRE tuaj yeem tswj xyuas cov khoom tsim khoom, kos npe, ntim thiab xa cov sijhawm rau kev lag luam thiab thaj chaw.
Koj puas tuaj yeem muab AC90 rau modular builders?
Yog lawm.AC90 modular tsev cabletuaj yeem muab tau rau hauv cov kab hluav taws xob uas tau teev tseg, nrog rau kev tsim khoom thiab qhov project- tshwj xeeb ntim los txhawb kev tawm ntawm - qhov chaw ua haujlwm.
Koj puas tuaj yeem muab cov ntaub ntawv pov thawj?
Yog lawm. AC90 cable cov ntaub ntawv tuaj yeem muab rau kev tsim kho, npog cov qauv khoom, kev ntsuas, qhov ntev thiab muaj cov ntaub ntawv ua raws.
 

 

Hot Tags: AC90 tooj liab cable dub liab 2c rau cable trough thaiv 600v, Tuam Tshoj ac90 tooj liab cable dub liab 2c rau cable troughwiring 600v manufacturers, lwm tus neeg, Hoobkas

Send Inquiry