Tus coj
RE: Class 1 khoom tooj liab conductor
RM: Class 2 stranded tooj liab conductor
Rwb thaiv tsevTom ntej: PVC (Polyvinyl Chloride)
FillerTom ntej: PVC (Polyvinyl Chloride)
SheathTom ntej: PVC (Polyvinyl Chloride)
Kev ntsuas voltage Uo / U: 0.6/1kV
Temperature Rating Kho:-15 degree rau +70 degree
Flexed:-5o degree rau +50 degree
Yam tsawg kawg Bending Radius Kho:12 x zuag qhia tag nrho
Cov qauv
IEC 60502-1
nplaim taws retardant raws li lEC/EN 60332-1-2
Daim ntawv thov
NYY cable yog lub zog thiab tswj cable rau kev teeb tsa ruaj khov, tsim los rau kev xa hluav taws xob thiab kev tswj hwm hauv ntau qhov chaw. Nws muaj ntau yam kev siv thiab tuaj yeem siv hauv tsev, sab nraum zoov, hauv av, hauv pob zeb, thiab hauv qab dej. Nws muaj zog adaptability thiab kev ntseeg tau.
NYY cable feem ntau yog siv rau hauv cov chaw tsim khoom, kev tsim kho, kev tsim kho hauv nroog thiab lwm yam kev lag luam, thiab tshwj xeeb tshaj yog tsim nyog rau kev ruaj khov ntawm kev xa hluav taws xob thiab khoom siv. Nws cov tawv tawv sab nrauv zoo tiv thaiv kev puas tsuaj rau lub cev sab nraud thiab tiv thaiv kev ya raws, corrosive tshuaj thiab cov neeg kho tshuab poob siab los ntawm kev cuam tshuam cov qauv sab hauv ntawm lub cable. Txawm hais tias nyob rau hauv qhov chaw kub, ntub lossis txias, NYY cable tuaj yeem tswj xyuas hluav taws xob ruaj khov.

Feature

NYY cable yog rugged thiab ntau yam zog thiab tswj cable tsim rau kev teeb tsa ruaj khov hauv ntau qhov chaw. Nws nta Class 1 khoom tooj liab conductors (RE) los yog Class 2 stranded tooj liab conductors (RM), xyuas kom meej hluav taws xob conduction thaum tswj kev yooj yim kom tau raws li qhov sib txawv installation xav tau. Tus neeg xyuas pib yog insulated nrog PVC (polyvinyl chloride), muab hluav taws xob zoo heev thiab kev tiv thaiv los ntawm ib puag ncig yam.
Lub cable kev tsim kho muaj xws li PVC muab tub lim thiab ib lub tsho PVC sab nrauv, ob qho tib si uas muab kev tiv thaiv cov neeg kho tshuab ntxiv thiab txhim kho lub cable tiv thaiv kev puas tsuaj, tshuaj lom neeg, thiab UV hluav taws xob. Lub tsho PVC sab nrauv kuj ua kom ntseeg tau tias lub cable tuaj yeem tiv taus sab nraum zoov, ua rau nws zoo tagnrho rau siv rau hauv qhov chaw raug, hauv av, lossis kos rau hauv pob zeb.
Daim ntawv pov thawj
NYY cable tau dhau daim ntawv pov thawj CE, qhia tias cov khoom ua tau raws li tag nrho cov lus qhia thiab cov kev cai, tshwj xeeb tshaj yog nyob rau hauv kev nyab xeeb hluav taws xob, kev nyab xeeb thiab kev tiv thaiv ib puag ncig. Nws txoj kev ua raws li txoj cai tseem ua rau cov neeg siv khoom ntseeg siab ntawm cov khoom zoo thiab kev nyab xeeb. Nrog rau daim ntawv pov thawj CE, NYY cable ua kom ntseeg tau tias nws ua tau raws li kev tiv thaiv ib puag ncig niaj hnub thiab cov qauv kev nyab xeeb thaum muab kev xa hluav taws xob txhim khu kev qha, thiab tsim nyog rau ntau lub sijhawm siv hluav taws xob uas xav tau kev teeb tsa hauv av lossis sab nraum zoov.

Pob

Cov kab ntau lawm

GERITEL Hlau muaj ntau dua 100 cov kab ntau lawm rau cov khoom siv hlau thiab cable, thiab cov khoom siv cable tau txais kev tsim khoom siv tag nrho. Lub precision ntawm automated ntau lawm cov cuab yeej tuaj yeem ncav cuag 0.002mm, kom ntseeg tau tias tag nrho cov khoom tau dhau 100% kev xeem thiab cov ntawv cim digital. Lub tuam txhab muaj lub tsev khaws khoom loj loj nrog cov khoom tso tawm txhua hnub ntawm 3 lab meters, muaj zog scalability, xa khoom raws sijhawm, thiab lav koj lub lag luam. Peb muaj pab pawg muag khoom tshaj lij. Peb cov hluav taws xob cables tau xa mus rau ntau lub teb chaws thiab cheeb tsam thoob ntiaj teb, xws li Lebanon, Iraq, Myanmar, Philippines, Lub teb chaws Yelemees, Tebchaws Meskas, Sweden, South Africa thiab lwm lub tebchaws loj thiab cheeb tsam.
cov neeg siv khoom
Raws li ib tug kws tshaj lij hlau thiab cable export chaw tsim tshuaj paus, peb cov neeg muas zaub yog thoob plaws lub ntiaj teb no, thiab peb paub txog cov hlau thiab cable qauv ntawm txawv teb chaws. Peb tsis tsuas yog muaj cov neeg ua haujlwm thiab cov kws tshaj lij hluav taws xob hauv ntau lub tebchaws, tab sis kuj muaj pab pawg kws tshaj lij los muab kev txhawb nqa.

Tus khub

FAQ
Q: Dab tsi yog NYY cable?
N: Qhia tias lub cable yog siv rau kev xa hluav taws xob.
Y: Qhia tias PVC (polyvinyl chloride) yog siv los ua cov khoom siv rau txheej rwb thaiv tsev thiab lub tsho sab nrauv.
Y: Qhov thib ob "Y" qhia tias lub cable yog tsim los siv sab nraum zoov thiab tuaj yeem tiv taus ib puag ncig xws li ya raws thiab huab cua.
Q: Nyy tuaj yeem faus?
Cim npe nrov: nyy cable, Tuam Tshoj nyy cable manufacturers, lwm tus neeg, Hoobkas

| NO.OF CORE | NOMINAL CROSS SECTIONAL AREA mm2 ua |
CONDUCTOR HOM | NOMINAL THICKNESS OF INSULATION mm |
NOMINAL THICKNESS OF SHEATH mm |
NOMINAL ZAJ NKAUJ DIAMETER mm |
NOMINAL NYIAJ kg/km |
| 1 | 2.5 | RE | 0.8 | 1.4 | 6.15 | 62 |
| 1 | 4 | RE | 1 | 1.4 | 7.5 | 85 |
| 1 | 6 | RE | 1 | 1.4 | 7.5 | 108 |
| 1 | 10 | RM | 1 | 1.4 | 8.6 | 155 |
| 1 | 16 | RM | 1 | 1.4 | 9.6 | 218 |
| 1 | 25 | RM | 1.2 | 1.4 | 11.1 | 318 |
| 1 | 35 | RM | 1.2 | 1.4 | 12.1 | 414 |
| 1 | 50 | RM | 1.4 | 1.4 | 13.7 | 552 |
| 1 | 70 | RM | 1.4 | 1.4 | 15.5 | 750 |
| 1 | 95 | RM | 1.6 | 1.5 | 17.6 | 1020 |
| 1 | 120 | RM | 1.6 | 1.6 | 19.3 | 1259 |
| 1 | 150 | RM | 1.8 | 1.6 | 21 | 1546 |
| 1 | 185 | RM | 2 | 1.7 | 23.2 | 1913 |
| 1 | 240 | RM | 2.2 | 1.8 | 26.2 | 2471 |
| 1 | 300 | RM | 2.4 | 2 | 29.2 | 3097 |
| 2 | 1.5 | RE | 0.8 | 1.8 | 10 | 147 |
| 2 | 2.5 | RE | 0.8 | 1.8 | 10.7 | 179 |
| 2 | 4 | RM | 1 | 1.8 | 13 | 268 |
| 2 | 6 | RM | 1 | 1.8 | 14.2 | 337 |
| 2 | 10 | RM | 1 | 1.8 | 16.2 | 472 |
| 2 | 16 | RM | 1 | 1.8 | 18.2 | 644 |
| 3 | 1.5 | RE | 0.8 | 1.8 | 10.4 | 166 |
| 3 | 2.5 | RE | 0.8 | 1.8 | 11.3 | 212 |
| 3 | 4 | RE | 1 | 1.8 | 13.1 | 299 |
| 3 | 6 | RM | 1 | 1.8 | 15 | 402 |
| 3 | 10 | RM | 1 | 1.8 | 17.1 | 570 |
| 3 | 16 | RM | 1 | 1.8 | 19.2 | 789 |
| 3 | 25 | RM | 1.2 | 1.8 | 22.1 | 1141 |
| 3 | 35 | RM | 1.2 | 1.8 | 24.1 | 1462 |
| 3 | 50 | RM | 1.4 | 1.8 | 27.6 | 1964 |
| 3 | 70 | RM | 1.6 | 2.1 | 36.3 | 3635 |
| 3 | 95 | RM | 1.6 | 2.2 | 40 | 4488 |
| 4 | 1.5 | RE | 0.8 | 1.8 | 11.6 | 198 |
| 4 | 2.5 | RE | 0.8 | 1.8 | 12.1 | 252 |
| 4 | 4 | RM | 1 | 1.8 | 15.1 | 391 |
| 4 | 6 | RM | 1 | 1.8 | 16.5 | 465 |
| 4 | 10 | RM | 1 | 1.8 | 18.6 | 702 |
| 4 | 16 | RM | 1 | 1.8 | 21.1 | 992 |
| 4 | 25 | RM | 1.2 | 1.8 | 24.2 | 1431 |
| 4 | 35 | RM | 1.2 | 1.8 | 26.6 | 1861 |
| 4 | 50 | RM | 1.4 | 1.9 | 30.9 | 2535 |
| 4 | 70 | RM | 1.4 | 2.1 | 35.1 | 3441 |
| 4 | 95 | RM | 1.6 | 2.2 | 40.4 | 4691 |
| 4 | 120 | RM | 1.6 | 2.4 | 44.2 | 5757 |
| 4 | 150 | RM | 1.8 | 2.5 | 48.5 | 7095 |
| 4 | 185 | RM | 2 | 2.7 | 53.9 | 8810 |
| 4 | 240 | RM | 2.2 | 2.9 | 61.1 | 11400 |
| 5 | 1.5 | RE | 10.8 | 1.8 | 12 | 232 |
| 5 | 2.5 | RE | 10.8 | 1.8 | 13.1 | 302 |
| 5 | 4 | RM | 1 | 1.8 | 16.6 | 477 |
| 5 | 6 | RM | 1 | 1.8 | 18.2 | 618 |
| 5 | 10 | RM | 1 | 1.8 | 20.3 | 853 |
| 5 | 16 | RM | 1 | 1.8 | 23.1 | 1212 |
| 5 | 25 | RM | 0.8 | 1.8 | 26.6 | 280 |
| 7 | 1.5 | RE | 1 | 1.8 | 16.6 | 477 |
| 7 | 2.5 | RE | 0.8 | 1.8 | 14.1 | 368 |
| 12 | 1.5 | RE | 0.8 | 1.8 | 16.6 | 475 |
| 12 | 2.5 | RE | 0.8 | 1.8 | 18.2 | 628 |
| 14 | 1.5 | RE | 0.8 | 1.8 | 17.1 | 515 |
| 19 | 1.5 | RE | 0.8 | 1.8 | 18.9 | 648 |
| 19 | 2.5 | RE | 0.8 | 1.8 | 20.3 | 843 |
| 27 | 1.5 | RE | 0.8 | 1.8 | 22.6 | 895 |