American standard MC cable yog hlau clad cable, tseem hu ua MC hlau. Cov cable no yog siv rau kev kho kom zoo nkauj hauv tsev thiab kev tsim kho hauv North America, thiab tseem hu ua AC cable hauv khw Canadian. Yog tias cov tuam txhab hluav taws xob MC xav muag MC cables mus rau North American lag luam, cov khoom yuav tsum dhau kev soj ntsuam nruj nruj los ntawm Underwriters Laboratories (UL) hauv Tebchaws Meskas thiab tau txais ntawv pov thawj UL lossis cUL ntawv pov thawj. Qhia tias nws ua tau raws li cov qauv kev nyab xeeb ntawm Tebchaws Meskas.
Hlau clad xaim muaj cov tooj liab hlau, txheej rwb thaiv tsev, nylon sheath, hlau txheej txheej, thiab txheej tiv thaiv ntxiv. Muaj ob yam khoom siv rau cov hlau sab nrauv, hlau hlau thiab txhuas hlau, uas peb hu ua steel MC cable thiab txhuas MC cable raws li MC cable, tseem hu ua armored MC cable lossis hluav taws kub tswb mc cable, muaj hluav taws kub zoo heev vim nws cov hlau. sheath. Nws yog tshwj xeeb tshaj yog haum rau kev faib hluav taws xob hauv cov tsev thiab yog ib qho kev tiv thaiv zoo heev. Thaum nws tsim nyog los xov MC cov xov hlau hluav taws xob los ntawm cov pob zeb, pob zeb, lossis cov phab ntsa, siv MC cables tuaj yeem zam lub zog tsis tsim nyog. Vim lub kaw hlau sab nraud ntawm MC cables, lawv cov dej tsis zoo yog qhov zoo heev. Peb kuj hu MC cables dej pov thawj MC cables. Kuj tseem muaj hom tshwj xeeb ntawm MC cable, uas muaj roj hmab sheath ntawm cov hlau sab nraud. Peb hu nws cov roj hmab coated MC cable, uas tuaj yeem siv los ua lub twj tso kua mis submersible.
Feem ntau, cov qauv siv feem ntau ntawm MC cables suav nrog: 12 3 MC cable, 10 2 MC cable, 10 3 MC cable, 12 4 MC cable, 8 2 MC cable, 6 2 MC cable, 8 3 MC cable. Nws cov tub ntxhais hlau yog THHN hlau los yog THWN hlau los yog XHHW hlau. XHHW 2 cable yuav tsum tau ntawv pov thawj UL83 rau THHN THWN hlau, thiab UL44 ntawv pov thawj rau XHHW hlau XHHW-2 cable. Qhov ntsuas hluav taws xob ntawm MC cable yog 300V, thiab cov khoom siv rwb thaiv tsev yog PVC rwb thaiv tsev. Nws nominal cross-section yog 14mwg-450kcmil, thiab qhov voltage theem yog tsawg voltage cable. Tsis tas li ntawd, American standard MC xov hlau muaj nyob rau hauv ntau yam xim, nrog ib tug ntev ntev ntawm 250FT, 500FT, thiab 1000FT ib yob. Piv txwv li, 8 2 mc cable 250 ft, 12 2 mc cable 500 ft, thiab 10 3 mc cable 1000 ft
MC cables yog dav siv nyob rau hauv ntau yam kev siv fais fab. Nws feem ntau yog siv rau kev teeb tsa cov khoom siv hluav taws xob high-end hauv cov tsev thiab rau kev siv qhov chaw hluav taws xob ib puag ncig tseem ceeb, xws li nyob rau hauv cov xwm txheej uas cov tshuab hluav taws xob thiab cov cables nyob rau hauv ib puag ncig siab. MC cables tuaj yeem raug faus ncaj qha lossis ntsia rau hauv cov phab ntsa lossis thaj chaw cuam tshuam los ntawm kev faib hluav taws xob. Tsis tas li ntawd, MC cables kuj tuaj yeem siv rau lub zog thiab kev tswj xyuas Circuit Court hauv kev lag luam ib puag ncig thiab cov tshuab loj.
Ntxiv nrog rau nws cov kev tiv thaiv zoo heev, MC cables kuj muaj qhov zoo hauv qab no, suav nrog kev tiv thaiv corrosion, hluav taws kub, kev ua tau zoo ntawm hluav taws xob, kev teeb tsa yooj yim, muaj pes tsawg tus connectors, sealing waterproof, thiab siab ntev. Yog li, MC cables yog qhov tsim nyog rau kev siv ntau yam kev siv hluav taws xob, ua kom muaj kev ruaj ntseg thiab kev nyab xeeb ntawm kev xa hluav taws xob, thiab muaj cov ntawv thov dav dav thiab kev lag luam muaj peev xwm.























