PRODUCT REAL SHOT




16 AWG Zuag qhia tag nrho Shielded XLPE / PVC 600V Instrumentation Type TC-ER Cable rau Industrial Process Control & Instrument Signal Wiring
PRODUCT SPECIFICATIONS

Product Description
Lub XLPE/PVC, 600V Instrumentation, Hom TC-ER thiab Direct Burial Cables muaj tag nrho cov tooj liab liab Class B stranded conductors (ua khub los yog triads), them nrog Cross-txuas Polyethylene (XLPE) rwb thaiv tsev, tag nrho shielded los yog dub thiab ntaub thaiv npog tag nrho. Cov cables no yog siv rau hauv cov tshuab tswj, suab, intercom, tswb circuits thiab kev tswj fais fab.
Daim ntawv thov
-
Nyob rau hauv huab cua dawb, ducts, cable tais, conduit, raceways thiab ncaj qha faus
-
Pom zoo rau Chav Kawm I, Div. 2 cov chaw muaj kev phom sij rau ib NEC
-
Tso cai rau Exposed Run (ER) siv raws li NEC rau 3 los yog ntau dua conductors; ob lub conductors tsis muaj av xaim yog Hom TC nkaus xwb
Nta
- Rated ntawm 90℃ntub los yog qhuav
- Ripcord (raws li xav tau)
- Zoo heev tshav ntuj
- Raws li kev ntsuas txias khoov ntawm -25 degree
| SPECIFICATIONS | |
|
Tus neeg tsav tsheb suav |
Muaj nyob rau hauv 1-pair txog 36-pairs, thiab 1-triad txog 24-triads |
|
Tus coj |
Siab annealed liab qab tooj liab Class B |
|
Ntsuas Qhov Loj |
Muaj nyob rau hauv 18 lossis 16 AWG |
|
Rwb thaiv tsev |
Hla -txuas polyethylene (XLPE) |
| Xim Coding | Ib ICEA S-58-679 Txoj Kev 9, Table E-1 (dub-dawb-liab), ntxiv rau ib tus neeg xyuas pib ib khub / triad luam tawm rau kev txheeb xyuas; ntxiv xim coding xaiv muaj |
| Shield Options | Zuag qhia tag nrho (OS)Tug: Tag Nrho Txhuas Txhuas Polyester (mylar) ntawv ci hauv kev sib cuag nrog 20 AWG stranded tinned tooj liab ntws hlau Tus kheej thiab tag nrho (IS/OS): Kev sib xyaw ua ke ntawm ob tus neeg thiab tag nrho nrog Aluminium polyester (mylar) ntawv ci hauv kev sib cuag nrog 20 AWG stranded tinned tooj liab xaim |
| Jacket | Polyvinyl Chloride (PVC) |
|
Jacket Marking |
00000 FT GREATER WIRE CABLE XXAWG XX/PR (los yog TR) XLPE/PVC OS (los yog IS lossis IS/OS) 600V 90C WET OR DRY HOM TC-ER (UL) SUN RES DIR BUR UA HAUJ LWM MMDDYYYYY |
|
Ntim |
Tsis yog-rov qab ntoo reels hauv ntau qhov ntev thiab qhov ntev |
|
Kev Ua Raws Cai |
ASTM B3, ASTM B8, ASTM B33 UL® 44 TIAB SA 1277 UL 1685 (Kev ntsuas nplaim taws) ANSI/NEMA WC 57/ICEA S-73-532 |
|
Lwm yam kev ua raws cai |
EPA 40 CFR, Ntu 261 OSHA RoHS{0}}ua raws / RoHS 2-ua raws REACH-ua raws |
Zuag qhia tag nrho shielded
| Pair suav | Conductor Size AWG | Rwb thaiv tsev Thickness hauv (mm) |
Jacket Thickness hauv (mm) |
Kwv yees li. Zuag qhia tag nrho hauv (mm) |
Kwv yees li. Net nyhav lbs/kft (kg/km) |
|
1 |
18 | 0.030(0.76) | 0.045(1.14) | 0.32(8.2) | 45(61) |
| - | 18 | 0.030(0.76) | 0.045(1.14) | 0.34(8.6) | 55 (75) |
| 2 | 18 | 0.030(0.76) | 0.045(1.14) | 0.46(11.7) | 70(101) |
| 4 | 18 | 0.030(0.76) | 0.060(1.52) | 0.57(14.5) | 110(156) |
| 8 | 18 | 0.030(0.76) | 0.060(1.52) | 0.73(18.5) | 180(264) |
| 12 | 18 | 0.030(0.76) | 0.080(2.03) | 0.92(23.5) | 280(412) |
| 16 | 18 | 0.030(0.76) | 0.080(2.03) | 1.02(26.0) | 350(520) |
| 20 | 18 | 0.030(0.76) | 0.080(2.03) | 1.13(28.7) | 465(685) |
| 24 | 18 | 0.030(0.76) | 0.080(2.03) | 1.26(31.9) | 540(803) |
| 36 | 18 | 0.030(0.76) | 0.080(2.03) | 1.44(36.5) | 755 (1,117) |
| 1 | 16 | 0.030(0.76) | 0.045(1.14) | 0.35(8.8) | 60(82) |
| - | 16 | 0.030(0.76) | 0.045(1.14) | 0.37(9.3) | 70(102) |
| 2 | 16 | 0.030(0.76) | 0.045(1.14) | 0.50(12.7) | 95(140) |
| 4 | 16 | 0.030(0.76) | 0.060(1.52) | 0.62(15.7) | 170 (249) |
| 8 | 16 | 0.030(0.76) | 0.060(1.52) | 0.80(20.2) | 285(421) |
| 12 | 16 | 0.030(0.76) | 0.080(2.03) | 1.01(25.6) | 440(651) |
| 16 | 16 | 0.030(0.76) | 0.080(2.03) | 1.12(28.4) | 550(817) |
| 20 | 16 | 0.030(0.76) | 0.080(2.03) | 1.24(31.4) | 665(986) |
| 24 | 16 | 0.030(0.76) | 0.080(2.03) | 1.37(34.9) | 780(1,159) |
| 36 | 16 | 0.030(0.76) | 0.080(2.03) | 1.57(40.0) | 1,095(1,625) |
|
Ib leeg thiab Zuag qhia tag nrho shielded |
|||||
| Pair suav | Conductor Size AWG | Rwb thaiv tsev Thickness hauv (mm) |
Jacket Thickness hauv (mm) |
Kwv yees li. Zuag qhia tag nrho hauv (mm) |
Kwv yees li. Net nyhav lbs/kft (kg/km) |
|
2 |
18 | 0.030(0.76) | 0.045(1.14) | 0.50(12.8) | 80(112) |
| 4 | 18 | 0.030(0.76) | 0.060(1.52) | 0.62(15.7) | 100 (143) |
| 8 | 18 | 0.030(0.76) | 0.060(1.52) | 0.80(20.3) | 120(177) |
| 12 | 18 | 0.030(0.76) | 0.080(2.03) | 1.01(25.7) | 320(474) |
| 16 | 18 | 0.030(0.76) | 0.080(2.03) | 1.12(28.5) | 445(657) |
| 20 | 18 | 0.030(0.76) | 0.080(2.03) | 1.24(31.5) | 535(792) |
| 24 | 18 | 0.030(0.76) | 0.080(2.03) | 1.38(35.1) | 625(930) |
| 36 | 18 | 0.030(0.76) | 0.080(2.03) | 1.58(40.2) | 880(1,303) |
| 2 | 16 | 0.030(0.76) | 0.060(1.52) | 0.58(14.7) | 120 (175) |
| 4 | 16 | 0.030(0.76) | 0.060(1.52) | 0.67(17.0) | 185(271) |
| 8 | 16 | 0.030(0.76) | 0.080(2.03) | 0.91(23.1) | 350(517) |
| 12 | 16 | 0.030(0.76) | 0.080(2.03) | 1.10(27.9) | 485(719) |
| 16 | 16 | 0.030(0.76) | 0.080(2.03) | 1.22(31.0) | 610(906) |
| 20 | 16 | 0.030(0.76) | 0.080(2.03) | 1.36(34.4) | 740(1,095) |
| 24 | 16 | 0.030(0.76) | 0.080(2.03) | 1.51(38.3) | 870(1,289) |
| 36 | 16 | 0.030(0.76) | 0.110(2.79) | 1.79(45.5) | 1,320(1,963) |
CERTIFICATIONS

Ntim

Yob

Yas Reel

Ntoo Ntoo Reel
APPLICATION



CAS

BASF Ludwigshafen Verbund Site

MWRA Deer Island Wastewater Treatment Plant

Siemens Electronic Works Amberg Factory
Vim li cas thiaj xaiv peb
hauv ib qho - nres kev pabcuam
Dongguan Greater Wire & Cable Co., Ltd. yog tus kws tshaj lij engineering- qib cable chaw tsim khoom hauv Suav teb, muab cov ntawv pov thawj hluav taws xob cable daws teeb meem rau lub tsev, kev lag luam, tsuas, hluav taws xob, thiab kev tsim kho vaj tse thoob ntiaj teb.
Nrog rau 30,000 m² Hoobkas, 30 cov kab ntau lawm, cov kws tshaj lij engineers, thiab pab pawg tswj xyuas nruj, peb muab cov khoom lag luam txhim khu kev qha, traceable, thiab ua raws cov khoom siv cable rau kev siv engineering thoob ntiaj teb. Peb cov khoom tau txais kev txhawb nqa los ntawm cov ntawv pov thawj suav nrog SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, thiab ISO.
Peb tau cog lus rau kev nyab xeeb, kev ua tau zoo, pob tshab, thiab kev sib koom ua ke ntev -. Los ntawm kev tshuaj xyuas cov khoom siv raw mus rau kev kuaj cov khoom tiav, txhua batch yog ua tib zoo tswj xyuas kom ruaj khov kev ua tau zoo thiab siv tau qhov project.
Greater Cable - Certified Quality. Kev ntseeg tau. Engineering tus nqi.

COV TSWV YIM






GLOBAL CERTIFICATIONS

COV PHOOJ YWG

INTERNATIONL TRANSPORTATION
01
Hiav txwv Freight
Peb muab cov kev daws teeb meem hauv hiav txwv txhim khu kev qha rau loj - ntim xaj. Koj cov khoom tau ntim khoom ruaj ntseg thiab xa mus rau hauv cov thawv ntim khoom, xyuas kom tus nqi - xa mus rau cov chaw nres nkoj thoob ntiaj teb.
02
Cua Freight
Rau kev xa khoom sai, peb cov kev pabcuam huab cua ua kom koj cov khoom mus txog thoob ntiaj teb cov chaw sai sai, nrog kev ceev faj thiab taug qab tag nrho ntawm txoj kev.
03
International Express
Xav tau kev thauj mus los sai? Peb cov kev pabcuam nthuav qhia thoob ntiaj teb muab kev txiav txim me me mus rau nruab nrab kom tau txais txiaj ntsig zoo, muab lub qhov rooj - mus rau - qhov rooj pabcuam nrog - lub sijhawm taug qab kom muaj kev thaj yeeb nyab xeeb.

COOPERATIVE PARTNER
Peb tab tom nrhiav kev sib koom tes los nthuav peb txoj kev lag luam.










Tsuas qhia koj cov kev xav tau, tau txais peb cov kev daws teeb meem, paub meej cov qauv, thiab txaus siab rau kev tsim khoom sai, txhim khu kev qha thiab xa khoom thoob ntiaj teb - ua haujlwm nrog peb yog qhov yooj yim.
Peb qhov chaw nyob
Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Suav teb
Xov tooj
+86 136 6257 9592
+86 135 1078 4550
E -mail
manager01@greaterwire.com

FAQ
Hot Tags: 16 AWG Zuag qhia tag nrho Shielded XLPE / PVC 600V Instrumentation Hom TC-ER Cable, Tuam Tshoj 16 AWG Zuag qhia tag nrho Shielded XLPE / PVC 600V Instrumentation hom TC-ER Cable manufacturers, lwm tus neeg, Hoobkas