16 AWG Zuag qhia tag nrho shielded XLPE / PVC 600V Instrumentation Type TC-ER Cable

16 AWG Zuag qhia tag nrho shielded XLPE / PVC 600V Instrumentation Type TC-ER Cable
Details:
· PVC Overall Jacket
· Stranded Bare Copper Conductor
· Ripcord (raws li xav tau)
· Hla -txuas polyethylene (XLPE)
· Filler (raws li xav tau)
· Kev ntsuas hluav taws xob: 600V
· Kub: Rated ntawm 90℃ntub los yog qhuav
Ø Qhov Loj: 18AWG lossis 16AWG
Txheem: UL44 / UL1277
· Muaj nyob rau hauv 1-pair mus txog 36-pairs, thiab 1-triad txog 24-triads
· Xim: Per ICEA S-58-679 Txoj Kev 9, Table E-1 (dub-dawb-liab), ntxiv rau ib tus neeg xyuas pib ib khub / triad luam tawm rau kev txheeb xyuas; ntxiv xim coding xaiv muaj
Send Inquiry
Download
Kev piav qhia
Technical Parameters
Daim ntawv pov thawj

600V XLPE/PVC tray cable for wastewater treatment plant

PRODUCT REAL SHOT

 

shielded XLPE/PVC instrumentation cable for pharmaceutical plant
600V XLPE/PVC TC-ER instrumentation cable for food processing plant
600V XLPE/PVC TC-ER instrumentation cable for wastewater treatment plant

XLPE/PVC Type TC-ER cable for wastewater treatment plant

16 AWG Zuag qhia tag nrho Shielded XLPE / PVC 600V Instrumentation Type TC-ER Cable rau Industrial Process Control & Instrument Signal Wiring
Qhov no 16 AWG ib qho tag nrho cov ntaub thaiv npog muaj teeb liab cable yog tus qauvXLPE rwb thaiv tsev XLPE/PVC TC-ER instrumentation cable, manufactured raws li certifiedXLPE/PVC Hom TC-ER cable nrog RFH-2 rwb thaiv tsevthiab ntsuas ntawm 600V, uas txhawb kev hloov kho600V XLPE / PVC TC -ER instrumentation cable quotethiab ua haujlwm raws li tus nqi - zooIS/OS XLPE/PVC instrumentation cable hloovrau ib qho kev tiv thaiv thaiv thaiv thaiv qhov project. Tsim nrog Class B tag nrho annealed liab qab tooj liab conductors, XLPE core rwb thaiv tsev, aluminium polyester foil tag nrho cov ntaub thaiv npog ua ke nrog 20 AWG tinned tooj liab xaim thiab dub PVC txheej tsho, hom TC-ER tray cable raws li UL 1277 & UL 1685 qauv, rated 90-degree txias thiab kev ua tau zoo, hnub ci kev ua tau zoo. rau cable tais, conduit, ncaj qha faus thiab raug khiav installation nyob rau hauv kev tswj systems, tswb circuits thiab cov khoom siv zog tswj.
PRODUCT SPECIFICATIONS

 

30 pair shielded XLPE instrumentation cable 600V

Product Description

 

Lub XLPE/PVC, 600V Instrumentation, Hom TC-ER thiab Direct Burial Cables muaj tag nrho cov tooj liab liab Class B stranded conductors (ua khub los yog triads), them nrog Cross-txuas Polyethylene (XLPE) rwb thaiv tsev, tag nrho shielded los yog dub thiab ntaub thaiv npog tag nrho. Cov cables no yog siv rau hauv cov tshuab tswj, suab, intercom, tswb circuits thiab kev tswj fais fab.

Daim ntawv thov

 
  • Nyob rau hauv huab cua dawb, ducts, cable tais, conduit, raceways thiab ncaj qha faus

  • Pom zoo rau Chav Kawm I, Div. 2 cov chaw muaj kev phom sij rau ib NEC

  • Tso cai rau Exposed Run (ER) siv raws li NEC rau 3 los yog ntau dua conductors; ob lub conductors tsis muaj av xaim yog Hom TC nkaus xwb

Nta

 
  • Rated ntawm 90℃ntub los yog qhuav
  • Ripcord (raws li xav tau)
  • Zoo heev tshav ntuj
  • Raws li kev ntsuas txias khoov ntawm -25 degree
SPECIFICATIONS

Tus neeg tsav tsheb suav

Muaj nyob rau hauv 1-pair txog 36-pairs, thiab 1-triad txog 24-triads

Tus coj

Siab annealed liab qab tooj liab Class B

Ntsuas Qhov Loj

Muaj nyob rau hauv 18 lossis 16 AWG

Rwb thaiv tsev

Hla -txuas polyethylene (XLPE)
Xim Coding Ib ICEA S-58-679 Txoj Kev 9, Table E-1 (dub-dawb-liab), ntxiv rau ib tus neeg xyuas pib ib khub / triad luam tawm rau kev txheeb xyuas; ntxiv xim coding xaiv muaj
Shield Options Zuag qhia tag nrho (OS)Tug: Tag Nrho Txhuas Txhuas Polyester (mylar) ntawv ci hauv kev sib cuag nrog 20 AWG stranded tinned tooj liab ntws hlau
Tus kheej thiab tag nrho (IS/OS): Kev sib xyaw ua ke ntawm ob tus neeg thiab tag nrho nrog Aluminium polyester (mylar) ntawv ci hauv kev sib cuag nrog 20 AWG stranded tinned tooj liab xaim
Jacket Polyvinyl Chloride (PVC)

Jacket Marking

00000 FT GREATER WIRE CABLE XXAWG XX/PR (los yog TR) XLPE/PVC OS (los yog IS lossis IS/OS) 600V 90C WET OR DRY HOM TC-ER (UL) SUN RES DIR BUR UA HAUJ LWM MMDDYYYYY

Ntim

Tsis yog-rov qab ntoo reels hauv ntau qhov ntev thiab qhov ntev

Kev Ua Raws Cai

ASTM B3, ASTM B8, ASTM B33

UL® 44

TIAB SA 1277

UL 1685 (Kev ntsuas nplaim taws)

ANSI/NEMA WC 57/ICEA S-73-532

Lwm yam kev ua raws cai

EPA 40 CFR, Ntu 261

OSHA

RoHS{0}}ua raws / RoHS 2-ua raws

REACH-ua raws

Zuag qhia tag nrho shielded

Pair suav Conductor Size AWG Rwb thaiv tsev Thickness
hauv (mm)
Jacket Thickness
hauv (mm)
Kwv yees li. Zuag qhia tag nrho
hauv (mm)
Kwv yees li. Net nyhav
lbs/kft (kg/km)

1

18 0.030(0.76) 0.045(1.14) 0.32(8.2) 45(61)
- 18 0.030(0.76) 0.045(1.14) 0.34(8.6) 55 (75)
2 18 0.030(0.76) 0.045(1.14) 0.46(11.7) 70(101)
4 18 0.030(0.76) 0.060(1.52) 0.57(14.5) 110(156)
8 18 0.030(0.76) 0.060(1.52) 0.73(18.5) 180(264)
12 18 0.030(0.76) 0.080(2.03) 0.92(23.5) 280(412)
16 18 0.030(0.76) 0.080(2.03) 1.02(26.0) 350(520)
20 18 0.030(0.76) 0.080(2.03) 1.13(28.7) 465(685)
24 18 0.030(0.76) 0.080(2.03) 1.26(31.9) 540(803)
36 18 0.030(0.76) 0.080(2.03) 1.44(36.5) 755 (1,117)
1 16 0.030(0.76) 0.045(1.14) 0.35(8.8) 60(82)
- 16 0.030(0.76) 0.045(1.14) 0.37(9.3) 70(102)
2 16 0.030(0.76) 0.045(1.14) 0.50(12.7) 95(140)
4 16 0.030(0.76) 0.060(1.52) 0.62(15.7) 170 (249)
8 16 0.030(0.76) 0.060(1.52) 0.80(20.2) 285(421)
12 16 0.030(0.76) 0.080(2.03) 1.01(25.6) 440(651)
16 16 0.030(0.76) 0.080(2.03) 1.12(28.4) 550(817)
20 16 0.030(0.76) 0.080(2.03) 1.24(31.4) 665(986)
24 16 0.030(0.76) 0.080(2.03) 1.37(34.9) 780(1,159)
36 16 0.030(0.76) 0.080(2.03) 1.57(40.0) 1,095(1,625)

 

Ib leeg thiab Zuag qhia tag nrho shielded

Pair suav Conductor Size AWG Rwb thaiv tsev Thickness
hauv (mm)
Jacket Thickness
hauv (mm)
Kwv yees li. Zuag qhia tag nrho
hauv (mm)
Kwv yees li. Net nyhav
lbs/kft (kg/km)

2

18 0.030(0.76) 0.045(1.14) 0.50(12.8) 80(112)
4 18 0.030(0.76) 0.060(1.52) 0.62(15.7) 100 (143)
8 18 0.030(0.76) 0.060(1.52) 0.80(20.3) 120(177)
12 18 0.030(0.76) 0.080(2.03) 1.01(25.7) 320(474)
16 18 0.030(0.76) 0.080(2.03) 1.12(28.5) 445(657)
20 18 0.030(0.76) 0.080(2.03) 1.24(31.5) 535(792)
24 18 0.030(0.76) 0.080(2.03) 1.38(35.1) 625(930)
36 18 0.030(0.76) 0.080(2.03) 1.58(40.2) 880(1,303)
2 16 0.030(0.76) 0.060(1.52) 0.58(14.7) 120 (175)
4 16 0.030(0.76) 0.060(1.52) 0.67(17.0) 185(271)
8 16 0.030(0.76) 0.080(2.03) 0.91(23.1) 350(517)
12 16 0.030(0.76) 0.080(2.03) 1.10(27.9) 485(719)
16 16 0.030(0.76) 0.080(2.03) 1.22(31.0) 610(906)
20 16 0.030(0.76) 0.080(2.03) 1.36(34.4) 740(1,095)
24 16 0.030(0.76) 0.080(2.03) 1.51(38.3) 870(1,289)
36 16 0.030(0.76) 0.110(2.79) 1.79(45.5) 1,320(1,963)
 
CERTIFICATIONS

 

XLPE/PVC 600V Type TC-ER cable tray

Ntim

 

XLPE/PVC 600V Type TC-ER exposed run

Yob

shielded XLPE/PVC instrumentation cable for exposed run

Yas Reel

XLPE/PVC 600V Type TC-ER free air

Ntoo Ntoo Reel

APPLICATION

 

600V XLPE/PVC TC-ER cable direct burial
Hoobkas Automation
XLPE/PVC TC-ER instrumentation cable for indoor outdoor
Txheej txheem ntsuas
shielded XLPE/PVC instrumentation cable for direct burial
Kev Kho Dej Dej Tswj Systems
CAS

 

XLPE/PVC TC-ER instrumentation cable for cable tray

BASF Ludwigshafen Verbund Site

600V XLPE/PVC tray cable for manufacturing plant

MWRA Deer Island Wastewater Treatment Plant

XLPE/PVC 600V Type TC-ER indoor outdoor

Siemens Electronic Works Amberg Factory

Vim li cas thiaj xaiv peb

 

30Xyoo ntawm kev paub
hauv ib qho - nres kev pabcuam

Dongguan Greater Wire & Cable Co., Ltd. yog tus kws tshaj lij engineering- qib cable chaw tsim khoom hauv Suav teb, muab cov ntawv pov thawj hluav taws xob cable daws teeb meem rau lub tsev, kev lag luam, tsuas, hluav taws xob, thiab kev tsim kho vaj tse thoob ntiaj teb.

Nrog rau 30,000 m² Hoobkas, 30 cov kab ntau lawm, cov kws tshaj lij engineers, thiab pab pawg tswj xyuas nruj, peb muab cov khoom lag luam txhim khu kev qha, traceable, thiab ua raws cov khoom siv cable rau kev siv engineering thoob ntiaj teb. Peb cov khoom tau txais kev txhawb nqa los ntawm cov ntawv pov thawj suav nrog SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, thiab ISO.

Peb tau cog lus rau kev nyab xeeb, kev ua tau zoo, pob tshab, thiab kev sib koom ua ke ntev -. Los ntawm kev tshuaj xyuas cov khoom siv raw mus rau kev kuaj cov khoom tiav, txhua batch yog ua tib zoo tswj xyuas kom ruaj khov kev ua tau zoo thiab siv tau qhov project.

Greater Cable - Certified Quality. Kev ntseeg tau. Engineering tus nqi.

shielded XLPE/PVC instrumentation cable for indoor outdoor
 
15K
Kev Ua Haujlwm tiav
150+
cov neeg ua haujlwm tshaj lij
15K
zoo siab cov neeg siv khoom
92+
khoom plig & certifacates
COV TSWV YIM

 

600V XLPE/PVC TC-ER cable wet dry locations
 
shielded XLPE/PVC instrumentation cable for wet dry locations
 
600V XLPE/PVC TC-ER cable aerial installation
 
XLPE/PVC TC-ER instrumentation cable for conduit
 
XLPE/PVC 600V Type TC-ER conduit
 
shielded XLPE/PVC instrumentation cable for conduit
 
GLOBAL CERTIFICATIONS

 

600V XLPE/PVC TC-ER cable ducts

COV PHOOJ YWG
 

shielded XLPE/PVC instrumentation cable for aerial installation

INTERNATIONL TRANSPORTATION

 

01

Hiav txwv Freight

Peb muab cov kev daws teeb meem hauv hiav txwv txhim khu kev qha rau loj - ntim xaj. Koj cov khoom tau ntim khoom ruaj ntseg thiab xa mus rau hauv cov thawv ntim khoom, xyuas kom tus nqi - xa mus rau cov chaw nres nkoj thoob ntiaj teb.

02

Cua Freight

Rau kev xa khoom sai, peb cov kev pabcuam huab cua ua kom koj cov khoom mus txog thoob ntiaj teb cov chaw sai sai, nrog kev ceev faj thiab taug qab tag nrho ntawm txoj kev.

03

International Express

Xav tau kev thauj mus los sai? Peb cov kev pabcuam nthuav qhia thoob ntiaj teb muab kev txiav txim me me mus rau nruab nrab kom tau txais txiaj ntsig zoo, muab lub qhov rooj - mus rau - qhov rooj pabcuam nrog - lub sijhawm taug qab kom muaj kev thaj yeeb nyab xeeb.

bare copper conductor XLPE/PVC TC-ER instrumentation cable
COOPERATIVE PARTNER

 

Peb tab tom nrhiav kev sib koom tes los nthuav peb txoj kev lag luam.

fully annealed bare copper XLPE/PVC TC-ER instrumentation cable
bare copper conductor 600V instrumentation cable
XLPE/PVC Type TC-ER cable with fully annealed bare copper
Class B stranded copper XLPE/PVC TC-ER instrumentation cable
Class B compressed strand XLPE/PVC TC-ER instrumentation cable
ASTM B8 copper conductor XLPE/PVC TC-ER instrumentation cable
XLPE/PVC Type TC-ER cable with ASTM B8 copper conductor
ASTM B33 tinned copper drain wire 600V instrumentation cable
ASTM B33 tinned copper drain wire shielded tray cable 600V
XLPE/PVC Type TC-ER cable with cross-linked polyethylene insulation
Yuav koom tes nrog peb li cas?

Tsuas qhia koj cov kev xav tau, tau txais peb cov kev daws teeb meem, paub meej cov qauv, thiab txaus siab rau kev tsim khoom sai, txhim khu kev qha thiab xa khoom thoob ntiaj teb - ua haujlwm nrog peb yog qhov yooj yim.

Peb qhov chaw nyob

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Suav teb

Xov tooj

+86 136 6257 9592

+86 135 1078 4550

E -mail

manager01@greaterwire.com

XLPE/PVC Type TC-ER cable with XLPE insulation
FAQ

 

Dab tsi yog cov khoom siv rwb thaiv tsev tau txais los ntawm 16 AWG tag nrho cov ntaub thaiv npog TC-ER cable?
Nws nta cross- txuas polyethylene rwb thaiv tsev, cais raws li kev tsim nyogXLPE rwb thaiv tsev XLPE/PVC TC-ER instrumentation cable, thiab ua tau raws li cov lus qhia ntawmXLPE/PVC Hom TC-ER cable nrog RFH-2 rwb thaiv tsevrau ruaj khov siab -kub ua haujlwm.
Koj puas tuaj yeem muab cov lus hais rau qhov 600V instrumentation tray cable?
Yog lawm, peb tuaj yeem muab cov qauv tsim600V XLPE / PVC TC -ER instrumentation cable quoteraws li koj xav tau khub kom muaj nuj nqis, tag nrho ntev thiab ntim khoom.
Puas yog qhov no siv tau los ua ib qho kev hloov pauv rau cov laus muaj teeb liab cables?
Tseeb tiag, nws ua haujlwm raws li kev ntseeg tauIS/OS XLPE/PVC instrumentation cable hloovrau cov chaw uas tsuas yog yuav tsum muaj kev tiv thaiv tag nrho es tsis txhob siv ob tus tib neeg- thiab - kev tiv thaiv tag nrho.
Qhov kev teeb tsa thiab ib puag ncig zoo li cas qhov no TC-ER cable txhawb nqa?
Qhov no 600V Hom TC-ER cable tuaj yeem muab tso rau hauv huab cua dawb, ducts, cov tais, cov kav dej thiab cov faus ncaj qha, tau pom zoo rau Chav Kawm I Div.2 qhov chaw muaj kev phom sij, nrog rau UV tiv thaiv zoo heev thiab qis - kub bending kev ua tau zoo mus rau -25℃.

 

Hot Tags: 16 AWG Zuag qhia tag nrho Shielded XLPE / PVC 600V Instrumentation Hom TC-ER Cable, Tuam Tshoj 16 AWG Zuag qhia tag nrho Shielded XLPE / PVC 600V Instrumentation hom TC-ER Cable manufacturers, lwm tus neeg, Hoobkas

Send Inquiry