UL44 RHH Hlau Chaw tsim tshuaj paus rau OEM Thiab Project Supply

UL44 RHH Hlau Chaw tsim tshuaj paus rau OEM Thiab Project Supply
Details:
· Tus neeg xyuas pib: Cov av liab qab tooj liab rau ASTM B3, Class B compressed stranded tooj liab ib ASTM B3 thiab B8, los yog 19-strand ua ke unilay tooj liab rau ASTM B3 thiab B787
· Rwb thaiv tsev: Hla Linked Polyethylene (XLPE) Hom RHH/RHW-2 los yog USE-2, Kub Kub, Moisture thiab Abrasion Resistant
Lub hwj chim: 600V / 1000V / 2000V
Send Inquiry
Download
Kev piav qhia
Technical Parameters
Daim ntawv pov thawj

Dongguan Greater Wire & Cable Co., Ltd. yog ib qho ntawm cov ua lag luam thiab cov neeg muag khoom ntawm ul44 rhh xaim chaw tsim tshuaj paus rau oem thiab qhov project mov hauv Suav teb, kuj txhawb kev pabcuam customized. Thov so assured mus yuav cov lag luam wholesale ntev ul44 rhh hlau chaw tsim tshuaj paus rau oem thiab peb tes num mov ua nyob rau hauv Suav teb nov los ntawm peb lub hoobkas. Yog tias koj muaj lus nug txog cov qauv dawb, thov koj xa email rau peb.

 

RHH cable for modular MEP systems

PRODUCT REAL SHOT

 

RHH wire for containerized electrical rooms
RHH wire for modular data center power distribution
RHH wire for aaprefabricated data center electrical systems

RHH cable for prefabricated data center electrical systems

Factory Production Custom Identification and Stable Bulk Delivery rau B2B Buyers
Raws li ib tugUL44 RHH Hlau Chaw tsim tshuaj paus, GERITEL WIRE tsom rau kev tsim khoom ruaj khov rau cov neeg xa khoom, cov neeg tsim hluav taws xob, OEM manufacturers thiab cov neeg yuav khoom. Cov khoom siv stranded tooj liab conductors nrog thermoset rwb thaiv tsev rau 90℃qhuav - qhov chaw pabcuam thiab tuaj yeem tsim rau cov kev xav tau sib txawv. Peb lub Hoobkas RHH hlau txhawb kev luam ntawv, rwb thaiv tsev xim, reel lengths, ntim thiab project labeling kom yooj yim rau kev yuav khoom thiab kev ua haujlwm- chaw tswj. OEM RHH cable xaj tuaj yeem npaj tau raws li qhov kev thov rov ua dua, ntim khoom lossis lub sijhawm ua haujlwm theem, pab B2B cov neeg siv khoom tswj hwm cov lus qhia tshwj xeeb thaum txo cov khoom siv tsis yooj yim.
PRODUCT SPECIFICATIONS

 

RHH wire for mobile building electrical systems

Daim ntawv thov thiab piav qhia

 

GERITEL WIRE's SES-2 600 Volts lossis RHH/RHW-2 1000 Volts fais fab cables yog tsim rau siv nyob rau hauv ntub thiab qhuav, conduits, ducts, troughs, ncaj qha faus, aerial txhawb los ntawm ib tug neeg xa xov, thiab qhov twg superior hluav taws xob khoom xav tau. Cov cables no muaj peev xwm ua haujlwm tsis tu ncua ntawm tus neeg xyuas pib qhov kub tsis tshaj 90℃rau kev ua haujlwm ib txwm nyob hauv qhov chaw ntub thiab qhuav, 130℃rau kev kub ceev, thiab 250℃rau luv luv Circuit Court tej yam kev mob. Rated rau 1000 lb / ft siab kawg sidewall siab.

SPECIFICATIONS
ASTM B3 Mos lossis Annealed Copper Hlau
· ASTM B8 Concentric-Lay-Tshuaj Copper Conductors
· ASTM B787 19 Hlau Combination Unilay-Tshuaj Copper Conductors
· UL 44 Thermoset-Insulated Hlau thiab Cables
UL 854 Kev Pabcuam Nkag Cable
· ICEA S-95-658 (NEMA WC70) Fais Fab Cables Rated 2000 Volts los yog tsawg dua rau kev faib hluav taws xob hluav taws xob
· RoHS-2 (European Directive 2011/65/EU)

Table 1 – Qhov hnyav thiab ntsuas

Cond. Loj Strand suav Diameter tshaj tus neeg xyuas pib Insul. Thickness Rwb thaiv tsev xim Kwv yees li. OD Tooj Luj Kwv yees li. Qhov hnyav

AWG/Kcmil

Tsis muaj Strands nti mil nti lb/1000 ft lb/1000 ft
14 7 0.070

45

BK 0.161 12 20
12 Khoom 0.080 45 BK 0.174 19 28
12 7 0.088 45 BK 0.179 20 28
10 7 0.113 45 BK 0.203 32 42
8 7 0.141 60 BK 0.259 95 67
6 7 0.177 60 BN 0.300 81 102
4 7 0.225 60 BK 0.345 128 153
3 7 0.252 60 BK 0.378 162 191
2 7 0.282 60 PEB 0.403 205 244
1 19 0.322 80 BK 0.481 258 304
1/0 19 0.361 80 BK 0.522 325 390
2/0 19 0.405 80 GN 0.564 410 481
3/0 19 0.456 80 BK 0.616 518 598
4/0 19 0.512 80 GN 0.672 653 742
250 37 0.558 95 BK 0.748 771 884
300 37 0.610 95 BK 0.801 926 1023
350 37 0.661 95 BK 0.851 1081 1213
400 37 0.705 95 BK 0.896 1235 1345
500 37 0.789 95 BN 0.956 1544 1696
600 61 0.865 110 YW 1.085 1853 2028
750 61 0.968 110 GN 1.171 2315 2492
1000 61 1.117 110 BK 1.337 3088 3283
Txhua qhov loj me yog nominal thiab raug rau kev tsim khoom ua haujlwm ntev
◊ Cable cim nrog lub cim no yog cov khoom lag luam txheem
• TBA cov lis dej num yog kev kwv yees nkaus xwb thiab cov khoom tiag yuav txawv. Thov tos kom txog thaum lub Tshuag code raug xa mus yuav cov khoom txuas thiab / lossis fittings.

Table 2 – Cov ntaub ntawv hluav taws xob thiab engineering

Cond. Loj Min Khoov
Radius
Max rub
Kev ntxhov siab
DC Resistance @
25 degree
AC Resistance @
75 degree
Inductive Reactance
@60Hz
Tso cai Ampacity
Ntawm 75 degree
Tso cai Ampacity
Ntawm 90 degree

AWG/Kcmil

nti lb Ω / 1000 ft Ω / 1000 ft Ω / 1000 ft Amp Amp
14 0.6 32 2.631 3.170 0.058 20 25
12 0.7 52 1.662 2.002 0.054 25 30
12 0.7 52 1.662 2.002 0.054 25 30
10 0.8 83 1.040 1.253

0.050

35 40
8 1.0 132 0.653 0.786 0.052 50 55
6 1.2 209 0.411 0.495 0.051 65 75
4 1.4 333 0.258 0.310 0.048 85 95
3 1.5 420 0.205 0.246 0.047 100 115
2 1.6 530 0.162 0.195 0.046 115 130
1 1.9 669 0.128 0.154 0.045 130 145
1/0 2.1 844 0.102 0.122 0.044 150 170
2/0 2.3 1064 0.081 0.097 0.043 175 195
3/0 2.5 1342 0.064 0.078 0.042 200 225
4/0 2.7 1692 0.051 0.062 0.041 230 260
250 3.0 2000 0.043 0.053 0.041 255 290
300 3.2 2400 0.036 0.045 0.041 285 320
350 3.4 2800 0.031 0.039 0.040 310 350
400 3.6 3200 0.027 0.035 0.040 335 380
500 3.8 4000 0.022 0.029 0.039 380 430
600 5.4 4800 0.018 0.025 0.039 420 475
750 5.9 6000 0.014 0.022 0.038 475 535
1000 6.7 8000 0.011 0.018 0.037 545 615
• Ampacities raws li 2023 NEC Table 310.16 thiab tsis suav nrog cov kev txwv tiv thaiv overcurrent hauv NEC 240.4(D) ntawm 15 Amps rau 14 AWG CU, 20
Amps rau 12 AWG CU, thiab 30 Amps rau 10 AWG CU (ywj siab ntawm tus neeg xyuas pib ntsuas kub thiab stranding yog qhov loj me nyob hauv lub rooj). Tsis tas li, saib NEC ntu
310.15 thiab 110.14(C) rau kev xav tau ntxiv.
• Inductive Reactance yog raws li cov khoom siv tsis yog -ferrous conduit nrog ib txoj kab uas hla qhov chaw nruab nrab - mus rau -center.
CERTIFICATIONS

 

RHH cable for mobile building electrical systems

Ntim

 

RHH wire for manufactured building interior wiring

Yob

thermoset RHH cable

Ntoo Ntoo Reel

RHH cable for manufactured building interior wiring

Loj Ntoo Reel

APPLICATION

 

RHH wire for energy storage electrical rooms
Underground Conduit Installation
RHH cable for energy storage electrical rooms
Conduit Txuas Txuas
RHH wire for BESS power distribution
Feeder Circuit Court Wiring
CAS

 

RHH cable for BESS power distribution

Tesla Gigafactory Texas

RHH wire for battery energy storage facility power

Stanford University California Asmeskas

RHH cable for battery energy storage facility power

Mayo Clinic Tsev Kho Mob, Saint Marys Campus

Vim li cas thiaj xaiv peb

 

30Xyoo ntawm kev paub
hauv ib qho - nres kev pabcuam

Dongguan Greater Wire & Cable Co., Ltd. yog tus kws tshaj lij engineering- qib cable chaw tsim khoom hauv Suav teb, muab cov ntawv pov thawj hluav taws xob cable daws teeb meem rau lub tsev, kev lag luam, tsuas, hluav taws xob, thiab kev tsim kho vaj tse thoob ntiaj teb.

Nrog rau 30,000 m² Hoobkas, 30 cov kab ntau lawm, cov kws paub txog engineers, thiab pab pawg tswj xyuas nruj, peb muab cov khoom lag luam txhim khu kev qha, traceable, thiab ua raws cov khoom siv cable rau kev siv engineering thoob ntiaj teb. Peb cov khoom tau txais kev txhawb nqa los ntawm cov ntawv pov thawj suav nrog SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, thiab ISO.

Peb tau cog lus rau kev nyab xeeb, kev ua tau zoo, pob tshab, thiab kev sib koom ua ke ntev -. Los ntawm kev tshuaj xyuas cov khoom siv raw mus rau kev kuaj cov khoom tiav, txhua batch yog ua tib zoo tswj xyuas kom ruaj khov kev ua tau zoo thiab siv tau qhov project.

Greater Cable - Certified Quality. Kev ntseeg tau. Engineering tus nqi.

RHH wire for BESS switchgear
 
15K
Kev Ua Haujlwm tiav
150+
cov neeg ua haujlwm tshaj lij
15K
zoo siab cov neeg siv khoom
92+
khoom plig & certifacates
COV TSWV YIM

 

RHH cable for BESS switchgear
 
RHH wire for BESS control rooms
 
RHH cable for BESS control rooms
 
RHH wire for energy storage inverter rooms
 
RHH cable for energy storage inverter rooms
 
RHH wire for energy storage power conversion systems
 
GLOBAL CERTIFICATIONS

 

RHH cable for energy storage power conversion systems

COV PHOOJ YWG
 

RHH wire for PCS electrical rooms

INTERNATIONL TRANSPORTATION

 

01

Hiav txwv Freight

Peb muab cov kev daws teeb meem hauv hiav txwv txhim khu kev qha rau loj - ntim xaj. Koj cov khoom tau ntim khoom ruaj ntseg thiab xa mus rau hauv cov thawv ntim khoom, xyuas kom tus nqi - xa mus rau cov chaw nres nkoj thoob ntiaj teb.

02

Cua Freight

Rau kev xa khoom sai, peb cov kev pabcuam huab cua ua kom koj cov khoom mus txog thoob ntiaj teb cov chaw sai sai, nrog kev ceev faj thiab taug qab tag nrho ntawm txoj kev.

03

International Express

Xav tau kev thauj mus los sai? Peb cov kev pabcuam nthuav qhia thoob ntiaj teb xa cov xaj me me mus rau nruab nrab kom tau txais txiaj ntsig zoo, muab lub qhov rooj - rau - qhov rooj pabcuam nrog - lub sijhawm taug qab kom muaj kev thaj yeeb nyab xeeb.

RHH cable for PCS electrical rooms
COOPERATIVE PARTNER

 

Peb tab tom nrhiav kev sib koom tes los nthuav peb txoj kev lag luam.

RHH wire for battery storage plant auxiliary power
RHH cable for battery storage plant auxiliary power
RHH wire for renewable energy electrical rooms
RHH cable for renewable energy electrical rooms
RHH wire for clean energy facilities
RHH cable for clean energy facilities
RHH wire for solar inverter rooms
RHH cable for solar inverter rooms
RHH wire for solar power distribution panels
RHH cable for solar power distribution panels
Yuav koom tes nrog peb li cas?

Tsuas qhia koj cov kev xav tau, tau txais peb cov kev daws teeb meem, paub meej cov qauv, thiab txaus siab rau kev tsim khoom sai, txhim khu kev qha thiab xa khoom thoob ntiaj teb - ua haujlwm nrog peb yog qhov yooj yim.

Peb qhov chaw nyob

Tsev 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Suav teb

Xov tooj

+86 136 6257 9592

+86 135 1078 4550

E -mail

manager01@greaterwire.com

RHH wire for solar plant auxiliary power systems
FAQ

 

Puas yog RHH tsawg- pa taws xoom-halogen data center cable?
Tsis tau. Kev tsim qauv RHH tsis yog los ntawm nws tus kheej lav LSZH cov khoom. Yog tias ib qhov project yuav tsum muaj tsawg - haus luam yeeb lossis halogen- ua haujlwm pub dawb, qhia qhov ntawd cais thiab txheeb xyuas cov khoom tseeb. GERITEL WIRE tuaj yeem tshuaj xyuas cov ntaub ntawv chaw RHH xaim raws li qhov xav tau kev ua haujlwm ntxiv.
RHH hlau puas tuaj yeem ntsia tau rau hauv cov ntaub ntawv chaw cable tais?
Tsis txhob xav tias kev pom zoo ntawm lub tais los ntawm RHH ib leeg. Kev siv lub tais nyob ntawm qhov tseeb cov khoom cim thiab txoj hauv kev. Rau RHH cable rau cov ntaub ntawv chaw teeb tsa, muab lub tais uas yuav tsum tau ua kom GERITEL WIRE tuaj yeem lees paub seb puas xav tau lub tais ntxiv - ntsuas kev tsim kho.
RHH hlau puas tuaj yeem siv rau hauv cov phiaj xwm hyperscale data center?
Yog lawm, rau cov chaw siv tau- sab qhuav- qhov chaw fais fab hluav taws xob tau teev tseg los ntawm qhov project engineer. GERITEL WIRE tuaj yeem muab RHH hlau rau cov chaw zov me nyuam cov ntaub ntawv hyperscale nrog cov ntawv sau rov qab, kev npaj reel thiab ntau lawm los txhawb kev tsim cov theem thiab siab - ntim khoom.
Puas yog RHH tsim nyog rau lub hom phiaj- chav fais fab tseem ceeb?
RHH tuaj yeem yog ib feem ntawm lub hom phiaj- qhov chaw tseem ceeb ntawm qhov chaw faib khoom ruaj khov thaum qhov qhuav - qhov chaw UL44 tus neeg xyuas pib hom sib phim rau kev tsim qauv engineering. GERITEL WIRE cov khoom sivLub luag haujlwm tseem ceeb RHH cablerau switchgear, vaj huam sib luag thiab feeder txoj kev, nrog rau qhov project-raws li kev tswj kom zoo thiab ntim.

 

Hot Tags: ul44 rhh hlau chaw tsim tshuaj paus rau oem thiab qhov project mov, Tuam Tshoj ul44 rhh hlau chaw tsim tshuaj paus rau oem thiab project mov manufacturers, lwm tus neeg, Hoobkas

Send Inquiry