Dongguan Greater Wire & Cable Co., Ltd. yog ib qho ntawm cov ua lag luam thiab cov neeg muag khoom ntawm ul44 rhh xaim chaw tsim tshuaj paus rau oem thiab qhov project mov hauv Suav teb, kuj txhawb kev pabcuam customized. Thov so assured mus yuav cov lag luam wholesale ntev ul44 rhh hlau chaw tsim tshuaj paus rau oem thiab peb tes num mov ua nyob rau hauv Suav teb nov los ntawm peb lub hoobkas. Yog tias koj muaj lus nug txog cov qauv dawb, thov koj xa email rau peb.

PRODUCT REAL SHOT




Factory Production Custom Identification and Stable Bulk Delivery rau B2B Buyers
PRODUCT SPECIFICATIONS

Daim ntawv thov thiab piav qhia
GERITEL WIRE's SES-2 600 Volts lossis RHH/RHW-2 1000 Volts fais fab cables yog tsim rau siv nyob rau hauv ntub thiab qhuav, conduits, ducts, troughs, ncaj qha faus, aerial txhawb los ntawm ib tug neeg xa xov, thiab qhov twg superior hluav taws xob khoom xav tau. Cov cables no muaj peev xwm ua haujlwm tsis tu ncua ntawm tus neeg xyuas pib qhov kub tsis tshaj 90℃rau kev ua haujlwm ib txwm nyob hauv qhov chaw ntub thiab qhuav, 130℃rau kev kub ceev, thiab 250℃rau luv luv Circuit Court tej yam kev mob. Rated rau 1000 lb / ft siab kawg sidewall siab.
| SPECIFICATIONS |
| ASTM B3 Mos lossis Annealed Copper Hlau |
| · ASTM B8 Concentric-Lay-Tshuaj Copper Conductors |
| · ASTM B787 19 Hlau Combination Unilay-Tshuaj Copper Conductors |
| · UL 44 Thermoset-Insulated Hlau thiab Cables |
| UL 854 Kev Pabcuam Nkag Cable |
| · ICEA S-95-658 (NEMA WC70) Fais Fab Cables Rated 2000 Volts los yog tsawg dua rau kev faib hluav taws xob hluav taws xob |
| · RoHS-2 (European Directive 2011/65/EU) |
Table 1 – Qhov hnyav thiab ntsuas
| Cond. Loj | Strand suav | Diameter tshaj tus neeg xyuas pib | Insul. Thickness | Rwb thaiv tsev xim | Kwv yees li. OD | Tooj Luj | Kwv yees li. Qhov hnyav |
|
AWG/Kcmil |
Tsis muaj Strands | nti | mil | nti | lb/1000 ft | lb/1000 ft | |
| 14 | 7 | 0.070 |
45 |
BK | 0.161 | 12 | 20 |
| 12 | Khoom | 0.080 | 45 | BK | 0.174 | 19 | 28 |
| 12 | 7 | 0.088 | 45 | BK | 0.179 | 20 | 28 |
| 10 | 7 | 0.113 | 45 | BK | 0.203 | 32 | 42 |
| 8 | 7 | 0.141 | 60 | BK | 0.259 | 95 | 67 |
| 6 | 7 | 0.177 | 60 | BN | 0.300 | 81 | 102 |
| 4 | 7 | 0.225 | 60 | BK | 0.345 | 128 | 153 |
| 3 | 7 | 0.252 | 60 | BK | 0.378 | 162 | 191 |
| 2 | 7 | 0.282 | 60 | PEB | 0.403 | 205 | 244 |
| 1 | 19 | 0.322 | 80 | BK | 0.481 | 258 | 304 |
| 1/0 | 19 | 0.361 | 80 | BK | 0.522 | 325 | 390 |
| 2/0 | 19 | 0.405 | 80 | GN | 0.564 | 410 | 481 |
| 3/0 | 19 | 0.456 | 80 | BK | 0.616 | 518 | 598 |
| 4/0 | 19 | 0.512 | 80 | GN | 0.672 | 653 | 742 |
| 250 | 37 | 0.558 | 95 | BK | 0.748 | 771 | 884 |
| 300 | 37 | 0.610 | 95 | BK | 0.801 | 926 | 1023 |
| 350 | 37 | 0.661 | 95 | BK | 0.851 | 1081 | 1213 |
| 400 | 37 | 0.705 | 95 | BK | 0.896 | 1235 | 1345 |
| 500 | 37 | 0.789 | 95 | BN | 0.956 | 1544 | 1696 |
| 600 | 61 | 0.865 | 110 | YW | 1.085 | 1853 | 2028 |
| 750 | 61 | 0.968 | 110 | GN | 1.171 | 2315 | 2492 |
| 1000 | 61 | 1.117 | 110 | BK | 1.337 | 3088 | 3283 |
| Txhua qhov loj me yog nominal thiab raug rau kev tsim khoom ua haujlwm ntev ◊ Cable cim nrog lub cim no yog cov khoom lag luam txheem • TBA cov lis dej num yog kev kwv yees nkaus xwb thiab cov khoom tiag yuav txawv. Thov tos kom txog thaum lub Tshuag code raug xa mus yuav cov khoom txuas thiab / lossis fittings. |
|||||||
Table 2 – Cov ntaub ntawv hluav taws xob thiab engineering
| Cond. Loj | Min Khoov Radius |
Max rub Kev ntxhov siab |
DC Resistance @ 25 degree |
AC Resistance @ 75 degree |
Inductive Reactance @60Hz |
Tso cai Ampacity Ntawm 75 degree |
Tso cai Ampacity Ntawm 90 degree |
|
AWG/Kcmil |
nti | lb | Ω / 1000 ft | Ω / 1000 ft | Ω / 1000 ft | Amp | Amp |
| 14 | 0.6 | 32 | 2.631 | 3.170 | 0.058 | 20 | 25 |
| 12 | 0.7 | 52 | 1.662 | 2.002 | 0.054 | 25 | 30 |
| 12 | 0.7 | 52 | 1.662 | 2.002 | 0.054 | 25 | 30 |
| 10 | 0.8 | 83 | 1.040 | 1.253 |
0.050 |
35 | 40 |
| 8 | 1.0 | 132 | 0.653 | 0.786 | 0.052 | 50 | 55 |
| 6 | 1.2 | 209 | 0.411 | 0.495 | 0.051 | 65 | 75 |
| 4 | 1.4 | 333 | 0.258 | 0.310 | 0.048 | 85 | 95 |
| 3 | 1.5 | 420 | 0.205 | 0.246 | 0.047 | 100 | 115 |
| 2 | 1.6 | 530 | 0.162 | 0.195 | 0.046 | 115 | 130 |
| 1 | 1.9 | 669 | 0.128 | 0.154 | 0.045 | 130 | 145 |
| 1/0 | 2.1 | 844 | 0.102 | 0.122 | 0.044 | 150 | 170 |
| 2/0 | 2.3 | 1064 | 0.081 | 0.097 | 0.043 | 175 | 195 |
| 3/0 | 2.5 | 1342 | 0.064 | 0.078 | 0.042 | 200 | 225 |
| 4/0 | 2.7 | 1692 | 0.051 | 0.062 | 0.041 | 230 | 260 |
| 250 | 3.0 | 2000 | 0.043 | 0.053 | 0.041 | 255 | 290 |
| 300 | 3.2 | 2400 | 0.036 | 0.045 | 0.041 | 285 | 320 |
| 350 | 3.4 | 2800 | 0.031 | 0.039 | 0.040 | 310 | 350 |
| 400 | 3.6 | 3200 | 0.027 | 0.035 | 0.040 | 335 | 380 |
| 500 | 3.8 | 4000 | 0.022 | 0.029 | 0.039 | 380 | 430 |
| 600 | 5.4 | 4800 | 0.018 | 0.025 | 0.039 | 420 | 475 |
| 750 | 5.9 | 6000 | 0.014 | 0.022 | 0.038 | 475 | 535 |
| 1000 | 6.7 | 8000 | 0.011 | 0.018 | 0.037 | 545 | 615 |
| • Ampacities raws li 2023 NEC Table 310.16 thiab tsis suav nrog cov kev txwv tiv thaiv overcurrent hauv NEC 240.4(D) ntawm 15 Amps rau 14 AWG CU, 20 Amps rau 12 AWG CU, thiab 30 Amps rau 10 AWG CU (ywj siab ntawm tus neeg xyuas pib ntsuas kub thiab stranding yog qhov loj me nyob hauv lub rooj). Tsis tas li, saib NEC ntu 310.15 thiab 110.14(C) rau kev xav tau ntxiv. • Inductive Reactance yog raws li cov khoom siv tsis yog -ferrous conduit nrog ib txoj kab uas hla qhov chaw nruab nrab - mus rau -center. |
|||||||
CERTIFICATIONS

Ntim

Yob

Ntoo Ntoo Reel

Loj Ntoo Reel
APPLICATION



CAS

Tesla Gigafactory Texas

Stanford University California Asmeskas

Mayo Clinic Tsev Kho Mob, Saint Marys Campus
Vim li cas thiaj xaiv peb
hauv ib qho - nres kev pabcuam
Dongguan Greater Wire & Cable Co., Ltd. yog tus kws tshaj lij engineering- qib cable chaw tsim khoom hauv Suav teb, muab cov ntawv pov thawj hluav taws xob cable daws teeb meem rau lub tsev, kev lag luam, tsuas, hluav taws xob, thiab kev tsim kho vaj tse thoob ntiaj teb.
Nrog rau 30,000 m² Hoobkas, 30 cov kab ntau lawm, cov kws paub txog engineers, thiab pab pawg tswj xyuas nruj, peb muab cov khoom lag luam txhim khu kev qha, traceable, thiab ua raws cov khoom siv cable rau kev siv engineering thoob ntiaj teb. Peb cov khoom tau txais kev txhawb nqa los ntawm cov ntawv pov thawj suav nrog SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, thiab ISO.
Peb tau cog lus rau kev nyab xeeb, kev ua tau zoo, pob tshab, thiab kev sib koom ua ke ntev -. Los ntawm kev tshuaj xyuas cov khoom siv raw mus rau kev kuaj cov khoom tiav, txhua batch yog ua tib zoo tswj xyuas kom ruaj khov kev ua tau zoo thiab siv tau qhov project.
Greater Cable - Certified Quality. Kev ntseeg tau. Engineering tus nqi.

COV TSWV YIM






GLOBAL CERTIFICATIONS

COV PHOOJ YWG

INTERNATIONL TRANSPORTATION
01
Hiav txwv Freight
Peb muab cov kev daws teeb meem hauv hiav txwv txhim khu kev qha rau loj - ntim xaj. Koj cov khoom tau ntim khoom ruaj ntseg thiab xa mus rau hauv cov thawv ntim khoom, xyuas kom tus nqi - xa mus rau cov chaw nres nkoj thoob ntiaj teb.
02
Cua Freight
Rau kev xa khoom sai, peb cov kev pabcuam huab cua ua kom koj cov khoom mus txog thoob ntiaj teb cov chaw sai sai, nrog kev ceev faj thiab taug qab tag nrho ntawm txoj kev.
03
International Express
Xav tau kev thauj mus los sai? Peb cov kev pabcuam nthuav qhia thoob ntiaj teb xa cov xaj me me mus rau nruab nrab kom tau txais txiaj ntsig zoo, muab lub qhov rooj - rau - qhov rooj pabcuam nrog - lub sijhawm taug qab kom muaj kev thaj yeeb nyab xeeb.

COOPERATIVE PARTNER
Peb tab tom nrhiav kev sib koom tes los nthuav peb txoj kev lag luam.










Tsuas qhia koj cov kev xav tau, tau txais peb cov kev daws teeb meem, paub meej cov qauv, thiab txaus siab rau kev tsim khoom sai, txhim khu kev qha thiab xa khoom thoob ntiaj teb - ua haujlwm nrog peb yog qhov yooj yim.
Peb qhov chaw nyob
Tsev 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Suav teb
Xov tooj
+86 136 6257 9592
+86 135 1078 4550
E -mail
manager01@greaterwire.com

FAQ
Hot Tags: ul44 rhh hlau chaw tsim tshuaj paus rau oem thiab qhov project mov, Tuam Tshoj ul44 rhh hlau chaw tsim tshuaj paus rau oem thiab project mov manufacturers, lwm tus neeg, Hoobkas