4 / 0 Thn Tooj Hlau 600V

4 / 0 Thn Tooj Hlau 600V
Paub meej:
Kub Kuj, Haum rau ntau yam ib puag ncig
UL BPS ntawv pov thawj, lub neej ntev
Siab compatibility, haum rau ntau yam ntawm cov khoom siv
Ntau tshaj 20 xyoo ntawm kev tsim ntau lawm
Kev ceev online tsocai & Cov qauv pub dawb muaj
Xa kev nug
Ces
Kev piav qhia
Technical Parameters
Daim ntawv pov thawj
thhn

 

4 / {0 thhn / thwn hlau

4 / {0} Hais txog cov xov xwm Asmeskas xaim hluav taws xob " Cov xaim xaim no yog qhov tseem ceeb tshaj plaws hauv cov tshuab hluav taws xob, siv los hloov hluav taws xob thaum muaj kev nyab xeeb thiab ua raws li cov khoom siv hluav taws xob hauv tebchaws. Thhak xaim yog insulated nrog ib txheej ntawm thermopastic cov khoom, feem ntau polyvinyl chloride (PVC), uas muab cov hluav taws xob hluav taws xob zoo. Cov rwb thaiv tsev no tiv thaiv cov hlau los ntawm ib puag ncig cov dej noo, tshuaj lom neeg, thiab kev puas tsuaj rau lub cev, ua kom muaj kev nyab xeeb kis ntawm lub zog. 4 / {{4 4}} Thnk Hlau yog ntsuas nyob rau 600 volts thiab haum rau ntau cov ntawv siv hluav taws xob. Qhov kev ntsuas hluav taws xob no yog txheem rau ntau yam kev lag luam thiab cov tshuab hluav taws xob, qhov twg xaim hluav taws xob, cov xaim xaim hluav taws xob, cov khoom noj khoom haus, thiab cov ceg nruab nrab. Lub Tebchaws Hluav Taws Xob Hluav Taws Xob (Nec) Qhia txog cov kev ntsuas hluav taws xob no kom paub meej tias cov kev xav tau ntawm cov hluav taws xob tsis muaj kev phom sij tsis muaj kev pheej hmoo ntawm kev ua haujlwm tsis zoo lossis tsis ua tiav.

 

Daim ntawv thov

 

 

4 / {0 Thhn Khij yog qhov ntsuas rau 600 volts, ua kom haum rau ntau qhov kev siv hluav taws xob. Qhov kev ntsuas hluav taws xob no puas yog txheem rau ntau cov lag luam thiab cov tshuab hluav taws xob, qhov twg cov hlau siv los nqa fais fab hla kev pabcuam, cov neeg noj mov, thiab cov voj ceg. Lub Tebchaws Hluav Taws Xob Hluav Taws Xob (Nec) Qhia txog cov kev ntsuas hluav taws xob no kom ntseeg tau tias cov hlau tuaj yeem ua kom cov hluav taws xob tsis muaj kev sib raug zoo lossis tsis ua tiav.

thhn wire application

 

Yam zoo

 

thhn copper wire

 

● Astm- B3, B8, thiab B787 (19 xaim hlau txheej txheem unilay-stranded)
● 150 UL Tus Qauv 83, 758, 1063, thiab 1581
● CSA C22.2 NO.75, T90 T90 NYLON SIPLONER LOS 1000 KCMIL
● ft 2 -} txhua qhov ntau
● Lub hnub tuaj yeem tiv taus - ntau thiab tsawg 8 AWG thiab loj dua
RoHS / CAWM ASIAN
● Ul & BPS ntawv pov thawj
● Thhn Thooj ● ant90 Nylon- cov chaw qhuav tsis pub dhau90 Degree C
● Cov chaw ntub dej tsis pub tshaj 75 degree lossis cov chaw qhuav tsis pub dhau 905 degree thaum raug roj
Thwn {-2- ntub dej tsis pub dhau 90 degree tsis pub tshaj 75 degree thaum raug roj

 

Daim ntawv muaj cai

 

 

Peb cov khoom tau ua tiav ntau yam kev muaj tswv yim muaj nuj nqis heev, suav nrog UL, TUV, SUV, EU CPR, CE, thiab lwm tus.

thhn wire certification

 

Lub thawv

 

THHN wire package

 

Chaw tsim khoom

 

thhn cable factory

 

Cov xov ntau dua yog ib qho kev lag luam siab tshaj lij tshwj xeeb hauv cov xov hlau thiab cov xov hlau thiab cov xaim hluav taws xob, cov xaim hluav taws xob muaj txiaj ntsig zoo rau kev ua lag luam thoob ntiaj teb. Lub tuam txhab muaj ntau xyoo kev sib tw, thiab cov khoom lag luam npog, pvc cable, xlpe cable, photovoltaic cable thiab cov kab ke tshwj xeeb. Peb cov khoom tau siv dav hauv lub zog, hluav taws xob, kev tsim kho, kev tsheb thauj mus los, kom cov neeg tuaj yeem tau txais cov khoom siv hluav taws xob txhim khu kev qha.

 

Rooj plaub

 

Company cases

 

Tus khub

 

greater wire Partner

 

Cov FAQ

 

Q: Ntau npaum li cas tam sim no tuaj yeem 4 / {1}} xaim nqa?

A: Qhov muaj peev xwm tam sim no ntawm 4 / {2}} tooj liab hlau nyob ntawm ntau yam kev mob, nrog rau cov xaim yog nyob rau hauv ib qho cua txias lossis cua dawb. Txhawm rau luam tawm tooj liab: 4 / {{4 4}} AWG hlau feem ntau muaj qhov ampacity ntawm 530 rau 2610 amps ntawm 90 degree (194 degree F).

Q: Dab tsi yog 4 / 0 tooj liab hlau siv rau?

A: 4 / {0 tooj liab hlau feem ntau yog siv rau hauv cov hluav taws xob uas yuav tsum muaj lub zog loj uas muaj peev xwm thiab muaj peev xwm ua tau zoo. Suav nrog: Kev siv cov ntaub ntawv muaj, hluav taws xob loj, thaub qab fais fab, thiab lwm tus

Q: Ntau npaum li cas ua 4 / 0 tooj liab hlau hnyav rau ib txhais ko taw?

A: Qhov hnyav ntawm 4 / 0 tooj liab yog kwv yees li}. 640 phaus ib txhais ko taw.

 

 

Cim npe nrov: 4 / {0 Thn Tooj hlau 6 {}}}}}} 0V, Tuam Tshoj 400V tuam ntxhab- cov chaw muag khoom, Hoobkas

217

 

Lead-dawb thermoplastic kub-resistant hluav taws xob xaim nrog nylon sheath (thylon sheath (Thwn / thwn {2}}). 600V. 90 degree
Tus neeg xyuas loj Tsis tau. & Nominal lub cheeb ntawm xaim Phab Ntsa Thickness Kwv yees tag nrho cov cheeb tsam Yam tsawg kawg nkaus rwb thaiv tsev tsis kam * Ampacity Cabinal nominal hnyav
(hli) (AWG) (hli) Pvc (hli) Nylon (hli) (hli) mω / Km 90 degree ntub 90 Degree qhuav Kg / km
Khov kho           Thwn Hwj chim  
1.6mm 14 1x1.60mm 0.4 0.10 2.60 130 35 35 22.62
2. {0 hli 12 1x2. 00 hli 0.4 0.10 3.00 110 40 40 33.57
2.6mm 10 1x2.60mm 0.5 0.10 3.80 120 55 55 55.78
3.2 hli 8 1x3.20mm 0.8 0.13 5.06 120 75 75 88.33
Tseg                
2. {0 mm² 14/7 7/0.60 0.4 0.10 2.80 130 30 35 23.51
3.5mm² 12/7 7/0.80 0.4 0.10 3.40 110 35 40 39.12
5.5mm² 10/7 7/1.00 0.5 0.10 4.20 120 50 55 60.56
8. {0 mm² 8/7 7/1.20 0.8 0.13 5.46 120 65 75 91.95
14mm² 6/7 7/1.60 0.8 0.13 6.66 100 95 105 151.77
22mm² 4/7 7/2.00 1 0.15 8.30 100 130 140 236.65
30mm² 2/7 7/2.30 1 0.15 9.20 100 160 170 306.50
38mm² 1-19 19/1.60 1.3 0.18 10.96 100 185 195 409.82
50mm² 1/0-19 19/1.80 1.3 0.18 11.96 100 220 235 509.05
60mm² 2/0-19 19/2.00 1.3 0.18 12.96 80 250 260 618.96
80mm² 3/0-19 19/2.30 1.3 0.18 14.46 80 300 320 804.44
100mm² 4/0-19 19/2.60 1.3 0.18 15.96 80 355 370 1013.94
125mm² 250 mcm 37/2.10 1.6 0.18 18.26 80 400 420 1296.37
150 hli 300 McM 37/2.30 1.6 0.20 19.70 80 440 475 1542.02
  350 MCM 37/2.47 1.6 0.20 20.90 60 505 523 1783.07
200mm² 400 MCM 37/2.60 1.6 0.20 21.80 60 540 570 1946.72
  500 mcm 37/2.95 1.6 0.20 24.25 60 620 655 2486.02
250 hli 500 mcm 61/2.30 1.6 0.20 24.30 60 620 655 2437.34
  600 MCM 61/2.52 1.8 0.23 26.76 60 690 710 2995.93
325mm² 650 MCM 61/2.60 1.8 0.23 27.46 60 720 770 3191.58
  750 MCM 61/2.82 1.8 0.23 29.36 60 785 820 3719.63
400mm² 800 MCM 61/2.90 1.8 0.23 30.16 60 810 875 3927.55
500 hli 1000 MCM 61/3.20 1.8 0.23 32.86 60 930 995 4750.91
Cov Qauv Txheej Txheem: PEC, NEC (raws li qhov kub ntawm 30 degree)

THHN wire certification