19/33kV ib leeg tub ntxhais aluminium MV unarmored cable feem ntau yog nruab nrog ib txheej hlau thaiv kom txo tau cov electromagnetic cuam tshuam ntawm cable. Lub shielding txheej feem ntau yog ua los ntawm tooj liab braid los yog tooj liab daim kab xev, uas muaj cov conductivity zoo heev thiab muaj peev xwm tiv thaiv tau cov kev cuam tshuam ntawm sab nraud electromagnetic cuam tshuam ntawm lub teeb liab. Qhov no tseem ceeb tshwj xeeb tshaj yog rau qee cov ntawv thov uas xav tau siab rau cov teeb liab zoo. Cov txheej thaiv tiv thaiv tsis tuaj yeem tsuas yog tiv thaiv lub teeb liab kev ruaj ntseg ntawm tus neeg xyuas pib sab hauv ntawm lub cable, tab sis tseem tiv thaiv cov cable los ntawm kev cuam tshuam electromagnetic rau ib puag ncig ib puag ncig thaum ua haujlwm.
yam ntxwv
MV unarmored cables yog resistant rau electromagnetic cuam tshuam, tshav kub, thiab hluav taws, thiab yog haum rau kev siv nyob rau hauv lub hwj chim mov systems nyob rau hauv loj industrial parks, kom ntseeg tau hais tias lub hwj chim faib ntawm cov khoom siv thiab ua kom muaj kev ruaj ntseg ntawm cov khoom siv.

Feature

• Tus neeg xyuas pib: Stranded Compacted Circular aluminium conductor raws li AS / NZS 1125
• Conductor Screen: Extruded Semi-conductive compound
• Rwb thaiv tsev: XLPE
• Rwb thaiv tsev Screen: Extruded
• Longitudinal Water thaiv: Dej thaiv daim kab xev saum toj thiab hauv qab strippable Semi-conductive compound
tooj liab screen (yeem)
• Hlau Rwb thaiv tsev Screen: Copper Wire Screen + helically siv tooj liab daim kab xev (E / F tam sim no muaj peev xwm - Raws li qhov yuav tsum tau ua)
• Metallic Sheath: Lead Alloy (yeem)
• Txheej txheej: Extruded Polyvinyl Chloride, Xim: Dub
(Alternative Sheath: PVC + HDPE Composite Sheath lossis LSZH Cov ntaub qhwv sab nraud thiab cov kev txwv yuav hloov raws li)
Daim ntawv pov thawj
Peb cov xov hlau thiab cables tau ntawv pov thawj SAA. Cov ntawv pov thawj cables txo cov kev pheej hmoo uas tej yaam num yuav ntsib thaum siv cov khoom uas tsis yog-tus qauv, xws li hluav taws xob tsis ua hauj lwm los yog teeb meem raws li txoj cai, ua kom muaj kev ruaj ntseg ntawm qhov project.

Pob

Cov kab ntau lawm

Greater Wire chaw tsim tshuaj paus siv tag nrho automated ntau lawm. Qhov tseeb ntawm cov khoom siv hluav taws xob tuaj yeem ncav cuag 0.002mm, thiab tag nrho cov khoom yog 100% tshuaj xyuas thiab cim digitally. Lub tuam txhab muaj lub tsev khaws khoom loj loj, nrog kev tsim khoom txhua hnub ntawm 300000 meters, scalability, thiab xa tuaj raws sij hawm los tiv thaiv koj lub lag luam. peb muaj kev muag khoom pab neeg. Peb cov khoom siv hluav taws xob photovoltaic tau muab rau ntau lub teb chaws thiab cheeb tsam thoob ntiaj teb, xws li Lebanon, Iraq, Myanmar, Philippines, Lub teb chaws Yelemees, Tebchaws Meskas, Sweden, South Africa, thiab lwm lub tebchaws thiab cheeb tsam.
Case

Tus khub

FAQ
Q: Koj puas xav tau cov txheej txheem ntxiv los tiv thaiv koj cov cables los ntawm kev laus?
Q: Nws puas tseem ceeb yog tias lub cable siv nyob rau hauv qhov chaw kub?
1. Cov khoom siv rwb thaiv tsev
Qhov kub thiab txias ib puag ncig yuav ua rau kom lub thermal aging ntawm cov khoom siv rwb thaiv tsev, ua rau cov txheej rwb thaiv tsev kom tawv, tawg lossis txawm tias tsis ua haujlwm, yog li cuam tshuam rau lub neej ntawm lub cable. Hauv cov ntawv thov kub kub, cov khoom siv hluav taws xob kub tiv thaiv hluav taws xob xws li cross-linked polyethylene (XLPE) lossis chloroprene roj hmab (CR) yuav tsum tau siv, uas muaj thermal stability ntau dua thiab tiv thaiv kev laus.
2. Txo lub peev xwm nqa tam sim no
Nyob rau hauv ib puag ncig kub, qhov kev tiv thaiv ntawm cable nce, ua rau muaj kev kub ntxhov ntau ntxiv, uas cuam tshuam rau lub peev xwm nqa tam sim no ntawm cable. Feem ntau hais lus, lub peev xwm nqa tam sim no ntawm cable yuav raug txo qis hauv qhov chaw kub. Lub derating yam ntawm lub cable tam sim no nqa peev xwm yuav tsum raug xa mus rau, thiab ib tug thicker cable yuav tsum tau tiv nrog tib yam tam sim no thov.
3. Kev pheej hmoo ntawm overheating
Qhov kub thiab txias ib puag ncig tuaj yeem yooj yim ua rau cov kab hluav taws xob kub siab tshaj nws qhov siab tshaj plaws kev ua haujlwm kub, ua rau muaj qhov tshwm sim overheating. Qhov no tuaj yeem ua rau muaj kev puas tsuaj rau cov txheej txheem rwb thaiv tsev lossis ua rau muaj kev phom sij luv luv. Nws yog ib qho tsim nyog los xyuas kom meej tias lub cable tau muab tso rau hauv qhov chaw zoo thaum tshav kub kub dissipation, thiab tsis txhob bundling los yog nteg ntau lub cables ntau heev.
4. Degradation ntawm cov ntaub ntawv sheath
Nyob rau hauv qhov kub thiab txias, cov ntaub ntawv sheath ntawm cable (xws li PVC) yuav maj mam poob elasticity thiab durability, thiab ces tawg los yog nkig. Nws raug nquahu kom siv cov ntaub qhwv nrog cov cua sov zoo dua, xws li chloroprene roj hmab lossis silicone roj hmab, nyob rau hauv qhov chaw kub kub kom ntev lub neej ntawm cov hlua sab nrauv.
5. Thermal expansion thiab mechanical stress
Qhov kub thiab txias yuav ua rau thermal expansion ntawm lub cable, uas yuav ua rau cov neeg kho tshuab kev ntxhov siab hloov, tshwj xeeb tshaj yog thaum lub installation qhov chaw me me thiab muaj ntau cov ntsiab lus kho. Thaum txhim kho, koj tuaj yeem txiav txim siab khaws qee qhov thermal expansion margins thiab siv cov ntaub ntawv nrog qee qhov kev hloov pauv kom tsis txhob cuam tshuam ntawm thermal expansion thiab contraction.
6. luv Circuit Court thiab overload muaj peev xwm
Nyob rau hauv ib puag ncig kub, lub luv luv-circuit kam rau ua ntawm lub cable yuav raug txwv. Yog li ntawd, thaum tsim kev tiv thaiv luv luv, qhov cuam tshuam ntawm qhov kub thiab txias yuav tsum tau txiav txim siab kom tsis txhob teeb tsa qhov luv luv luv tam sim no.
Cov kev ntsuas uas cov cables tuaj yeem coj mus rau hauv qhov chaw kub:
1. Xaiv cov kab hluav taws xob kub uas tiv thaiv kab mob los yog txhim kho cov kab hluav taws xob hluav taws xob (xws li kev txhim kho hauv qhov chaw txias lossis ua kom muaj cua).
2. Tsim cov cable loj raws li cov chaw tsim khoom cable derating yam.
3. Siv lub tsho tsim nyog thiab cov ntaub ntawv rwb thaiv tsev kom ncua kev laus thiab txhim kho qhov kub thiab txias.
Q: Cov kab hluav taws xob puas ua paug rau ib puag ncig?
Cim npe nrov: as/nzs1429.1 ib leeg tub ntxhais txhuas 19/33kv mv unarmored cable, Tuam Tshoj as/nzs1429.1 ib leeg tub ntxhais txhuas 19/33kv mv unarmored cable manufacturers, lwm tus neeg, Hoobkas


|
Tsis muaj
Cores
|
Core Cross
ntu
Thaj chaw
|
Nominal Dia
|
||
|
Hauv qab
nws yog xim hlau
npo
|
Hauv qab
nws yog xim hlau
npo
|
Zuag qhia tag nrho
|
||
|
Tsis muaj.
|
mm2 ua
|
mm
|
mm
|
mm
|
| 1 | 50 | 27.2 | 29.1 | 33.0 |
| 1 | 70 | 28.8 | 30.7 | 35.0 |
| 1 | 95 | 30.4 | 32.3 | 37.0 |
| 1 | 120 | 32 | 33.9 | 38.0 |
| 1 | 150 | 33.3 | 35.2 | 40.0 |
| 1 | 185 | 35 | 36.9 | 42.0 |
| 1 | 240 | 37.3 | 39.2 | 44.0 |
| 1 | 300 | 39.5 | 41.4 | 46.0 |
| 1 | 400 | 42.2 | 44.1 | 49.0 |
| 1 | 500 | 45.6 | 47.5 | 53.0 |
| 1 | 630 | 48.8 | 50.7 | 56.0 |
| 1 | 800 | 52.7 | 54.6 | 60.0 |
| 1 | 1000 | 57.2 | 59.1 | 65.0 |
|
No.of Cores
|
Core Cross sectional Area
|
Max. DC Resistance ntawm 20˚C
|
Max. AC Resistance ntawm 90˚C
|
Kwv yees li. Capacitance
|
Kwv yees li. Inductance
|
Kwv yees li.
Reactance |
Kev ntsuas tam sim no tsis tu ncua
|
|||||
|
Hauv av ntawm 20 degree
|
Hauv Duct ntawm
20 degree
|
Hauv huab cua ntawm 30 degree
|
||||||||||
|
Pav ca |
Trefoil
|
Pav ca
|
Trefoil
|
Pav ca
|
Trefoil
|
|||||||
|
Tsis muaj.
|
mm2 ua
|
Ω/km
|
Ω/km
|
µF/km
|
mH/km
|
Ω/km
|
Amps
|
|||||
| 1 | 50 | 0.641 | 0.822 | 0.14 | 0.486 | 0.153 | 157 | 152 | 146 | 142 | 189 | 184 |
| 1 | 70 | 0.443 | 0.568 | 0.15 | 0.450 | 0.141 | 192 | 186 | 178 | 176 | 236 | 230 |
| 1 | 95 | 0.32 | 0.411 | 0.17 | 0.429 | 0.135 | 229 | 221 | 213 | 210 | 287 | 280 |
| 1 | 120 | 0.253 | 0.325 | 0.18 | 0.409 | 0.128 | 260 | 252 | 242 | 240 | 332 | 324 |
| 1 | 150 | 0.206 | 0.265 | 0.19 | 0.397 | 0.125 | 288 | 281 | 271 | 267 | 376 | 368 |
| 1 | 185 | 0.164 | 0.211 | 0.21 | 0.383 | 0.120 | 324 | 317 | 307 | 303 | 432 | 424 |
| 1 | 240 | 0.125 | 0.162 | 0.23 | 0.367 | 0.115 | 373 | 367 | 356 | 351 | 511 | 502 |
| 1 | 300 | 0.1 | 0.130 | 0.25 | 0.354 | 0.111 | 419 | 414 | 402 | 397 | 586 | 577 |
| 1 | 400 | 0.0778 | 0.102 | 0.27 | 0.341 | 0.107 | 466 | 470 | 457 | 451 | 676 | 673 |
| 1 | 500 | 0.0605 | 0.080 | 0.3 | 0.327 | 0.103 | 525 | 530 | 510 | 505 | 760 | 750 |
| 1 | 630 | 0.0469 | 0.064 | 0.33 | 0.317 | 0.100 | 580 | 585 | 560 | 555 | 860 | 850 |
| 1 | 800 | 0.0367 | 0.051 | 0.36 | 0.306 | 0.096 | 650 | 655 | 620 | 615 | 960 | 950 |
| 1 | 1000 | 0.0291 | 0.043 | 0.4 | 0.297 | 0.093 | 715 | 705 | 670 | 665 | 1060 | 1050 |
| 20 | 25 | 35 | 40 | 45 | 50 | 55 | 60 |
| 1.08 | 1.04 | 0.96 | 0.91 | 0.87 | 0.82 | 0.76 | 0.71 |
| 10 | 15 | 25 | 30 | 35 | 40 | 45 | 50 |
| 1.07 | 1.04 | 0.96 | 0.93 | 0.89 | 0.85 | 0.80 | 0.76 |
|
No.of Cores
|
Core Cross sectional Area
|
Max. rub nro ntawm tus neeg xyuas pib
|
Charging Tam sim no ib theem
|
Zero sequence impedance
|
Hluav taws xob Stress ntawm Conductor Screen
|
Kev ntsuas luv luv ntawm Phase conductor
|
| Tsis muaj. | mm² os | kN kev | Amps / Km | Ohms/Km | kV / hli | kA, sec |
| 1 | 50 | 2.5 | 0.84 | 1.98 | 4.1 | 4.7 |
| 1 | 70 | 3.5 | 0.9 | 1.73 | 3.9 | 6.6 |
| 1 | 95 | 4.75 | 1.01 | 1.57 | 3.7 | 9.0 |
| 1 | 120 | 6 | 1.07 | 1.49 | 3.6 | 11.3 |
| 1 | 150 | 7.5 | 1.13 | 1.42 | 3.5 | 14.2 |
| 1 | 185 | 9.25 | 1.25 | 1.37 | 3.4 | 17.4 |
| 1 | 240 | 12 | 1.37 | 1.32 | 3.3 | 22.6 |
| 1 | 300 | 15 | 1.49 | 1.29 | 3.2 | 28.3 |
| 1 | 400 | 20 | 1.61 | 1.26 | 3.1 | 37.6 |
| 1 | 500 | 25 | 1.79 | 1.24 | 3.0 | 47.2 |
| 1 | 630 | 31.5 | 1.97 | 1.22 | 3.0 | 59.6 |
| 1 | 800 | 40 | 2.15 | 1.21 | 2.9 | 75.6 |