3 Core MV cable, tsim nyog tsim ntawm lub peev xwm nqa tam sim no thiab tus neeg xyuas pib ntu ntu, cov khoom siv thiab cov rwb thaiv tsev tuab ua rau lub cable ua haujlwm ruaj khov rau lub sijhawm ntev hauv kev ntsuas load, tsis txhob overload thiab overheating. Nws tiv thaiv kev cuam tshuam ntawm qhov kub thiab txias ntawm kev siv ib puag ncig, txoj kev xaim thiab lwm yam khoom siv hluav taws xob, thiab ua kom lub neej kev pab cuam ntawm cable.
Min. installation kub: 0 degree
Ua haujlwm kub: -25 degree rau +90 degree
Kev khiav hauj lwm kub ceev: 105 degree
(max. ua haujlwm ntawm 36 teev, ntawm 3 lub sijhawm rau 12 lub hlis sib law liag)
Max. Short Circuit kub: 250 degree
Daim ntawv thov
MV cable muaj qhov hluav taws kub zoo thiab hluav taws xob tiv thaiv kev ua haujlwm, thiab tsim nyog siv hauv tsev kawm ntawv thiab tsev kho mob. Nws feem ntau muab hluav taws xob rau teeb pom kev zoo, cua sov thiab khoom siv, ua kom muaj kev nyab xeeb thiab ruaj khov fais fab mov hauv qhov chaw tseem ceeb.

Feature

• Tus neeg xyuas pib: Stranded Compacted Circular txhuas tus neeg xyuas pib raws li AS / NZS 1125
• Conductor Screen: Extruded Semi-conductive compound
• Rwb thaiv tsev: XLPE
• Rwb thaiv tsev Screen: Extruded Semi-conductive compound
• Kev thaiv dej ntev: Dej thaiv daim kab xev saum toj thiab hauv qab tooj liab tshuaj ntsuam (Yeem)
• Hlau Rwb thaiv tsev Screen: Copper Wire Screen + helically siv tooj liab daim kab xev
• binder daim kab xev / sheath hla cov cores sib dhos
• Metallic Sheath: Lead Alloy (yeem)
• Txheej txheej: Extruded Polyvinyl Chloride, Xim: Dub
• Kev tiv thaiv kab tua kab: Polyamide Nylon (yeem)
(Alternative Sheath: PVC + HDPE Outer Sheath lossis LSZH Cov ntaub qhwv sab nraud thiab cov kev txwv yuav hloov raws li)
Daim ntawv pov thawj
Peb cov khoom tau ua tiav ntau yam kev lees paub thoob ntiaj teb, suav nrog SAA, UL, TUV, EU CPR, CE, ROHS, thiab lwm yam.

Pob

Hoobkas

Greater Wire Chaw tsim tshuaj paus lub Hoobkas tshaj lij cable muaj qhov chaw tsim khoom ntse thiab digital. Los ntawm seamless kev koom ua ke ntawm cov cuab yeej txiav-ntug, lub Hoobkas ua tiav tshem tawm cov kev ua yuam kev thiab qhov tsis xws luag uas yuav tshwm sim hauv cov txheej txheem kev sib dhos ib txwm muaj. Kev hloov mus rau digital manufacturing tsis tsuas yog ua kom muaj txiaj ntsig zoo xwb tab sis kuj qhia peb txoj kev cog lus los muab peb cov neeg siv khoom nrog cov khoom muaj kev ntseeg siab tshaj plaws. Lub tuam txhab ntse lub hauv paus ua kom muaj cov txheej txheem ntau lawm thiab tsis muaj kev ua yuam kev, txo qhov muaj peev xwm ntawm tib neeg muaj feem cuam tshuam thiab nce qhov ua tsis tiav yav dhau los. Muaj tseeb thiab automated soj ntsuam mechanism, lub Hoobkas nruj me ntsis ua raws li kev tswj kom zoo. Cov khoom raug tshuaj xyuas zoo txij thaum pib mus rau theem kawg ntawm kev tsim khoom. Kev tshawb pom cov duab digital ntse thiab laser thev naus laus zis tau siv los xyuas kom meej tias txhua yam khoom ua tau raws li cov qauv nruj nruj los ntawm peb lub tuam txhab. Qhov kev cog lus rau kev ua tau zoo no txuas ntxiv mus rau peb qhov kev tshuaj xyuas qhov tseeb, nrog cov cuab yeej siv tshuab ua haujlwm tau ua tiav qhov tseeb ntawm 0.002 hli, tshaj qhov ntsuas kev lag luam.
Greater Wire chaw tsim tshuaj paus muab qhov tseem ceeb heev rau lub luag hauj lwm ntawm kev sib raug zoo thiab nquag txhawb txoj kev loj hlob ruaj khov. Los ntawm kev siv cov txheej txheem ntsuab ntau lawm thiab cov ntaub ntawv zoo ib puag ncig, lub Hoobkas tau txo nws qhov cuam tshuam rau ib puag ncig. Nyob rau tib lub sijhawm, lub Hoobkas tseem koom nrog kev tsim kho hauv zej zog, muab kev ua haujlwm, thiab ua haujlwm rau pej xeem kev noj qab haus huv. Lub Hoobkas kuj tau tsim cov ncauj lus kom ntxaws txog kev txhim kho kom ruaj khov, uas yog lub hom phiaj los txo qhov cuam tshuam tsis zoo ntawm kev tsim khoom ntawm ib puag ncig los ntawm kev txuag hluav taws xob thiab txo qis emissions, peev txheej rov ua dua tshiab thiab lwm yam, thiab txhawb kev txhim kho kev lag luam mus ntev.
Case

Tus khub

FAQ
Q: Yuav ua li cas xaiv txoj cai cable qauv?
2. Lub peev xwm nqa tam sim no: Xaiv lub cable nrog lub peev xwm nqa tam sim no raws li qhov xav tau tiag tiag ntawm cov khoom siv. Feem ntau, lub peev xwm nqa tam sim no ntawm cable yog proportional rau qhov chaw hla ntu. Yog li ntawd, nws yog ib qho tsim nyog yuav tau xaiv ib lub cable uas tsim nyog rau qhov chaw seem raws li lub zog thiab cov khoom siv tam sim no kom tsis txhob overload thiab ua rau lub cable kom sov lossis puas.
3. Siv ib puag ncig: Yog tias siv nyob rau hauv qhov kub thiab txias ib puag ncig, nws yog ib qho tsim nyog los xaiv ib lub cable nrog qhov kub thiab txias uas ua tau raws li qhov yuav tsum tau ua. Waterproof cables yuav tsum tau siv nyob rau hauv qhov chaw ntub dej. Nyob rau hauv cov kua qaub, alkali los yog lwm yam corrosive ib puag ncig, cables nrog zoo corrosion kuj los yog roj kuj yuav tsum tau siv. Raws li txoj kev tso cable (xws li qhib nteg, zais nteg, underground lossis overhead nteg), xaiv ib hom cable nrog zoo hnav tsis kam thiab tensile kuj. Xav txog cov cable tensile, compressive thiab cuam tshuam tsis kam. Piv txwv li, cov cables siv rau ntawm cov khoom siv nquag txav yuav tsum muaj qhov yooj yim. Qee qhov chaw lossis cov khoom siv yuav muaj kev xav tau ntxiv, xws li tiv thaiv hluav taws xob cuam tshuam, nplaim hluav taws, hluav taws kub, thiab lwm yam. Xaiv cov cables tshwj xeeb nrog cov haujlwm sib xws raws li kev xav tau. Kev xaiv ntawm cov qauv cable yuav tsum ua raws li cov qauv kev lag luam uas cuam tshuam los yog lub teb chaws specifications kom muaj kev nyab xeeb thiab kev ntseeg siab ntawm cov cables.
Q: Koj puas yog cov chaw tsim khoom lossis tuam txhab lag luam?
Q: Peb tuaj yeem lav qhov zoo li cas?
Hot Tags: Tuam Tshoj peb core 12.7/24kv aluminium mv cable, Tuam Tshoj peb core 12.7/24kv aluminium mv cable manufacturers, lwm tus neeg, Hoobkas


|
Tsis muaj
Cores
|
Core Cross
ntu
Thaj tsam
|
Nominal Dia
|
||
|
Hauv qab
nws yog xim hlau
npo
|
Hauv qab
nws yog xim hlau
npo
|
Zuag qhia tag nrho
|
||
|
Tsis muaj.
|
mm2 ua
|
mm
|
mm
|
mm
|
| 3 | 35 | 21.1 | 22.6 | 54.0 |
| 3 | 50 | 22.2 | 23.7 | 57.0 |
| 3 | 70 | 23.8 | 25.3 | 60.0 |
| 3 | 95 | 25.4 | 26.9 | 64.0 |
| 3 | 120 | 27 | 28.5 | 67.0 |
| 3 | 150 | 28.3 | 29.8 | 70.0 |
| 3 | 185 | 30 | 31.5 | 74.0 |
| 3 | 240 | 32.3 | 33.8 | 80.0 |
| 3 | 300 | 34.5 | .36.0 | 85.0 |
| 3 | 400 | 37.2 | 38.7 | 91.0 |
| 3 | 500 | 40.6 | 42.1 | 99.0 |
|
No.of Cores
|
Core Cross sectional Area
|
Max. DC Resistance ntawm 20˚C
|
Max. AC Resistance ntawm 90˚C
|
Kwv yees li. Capacitance
|
Kwv yees li. Inductance
|
Kwv yees li.
Reactance |
Kev ntsuas tam sim no tsis tu ncua
|
||
| faus direet hauv av |
Nyob rau hauv ib tug faus duct
|
Hauv Cua
|
|||||||
|
Tsis muaj.
|
mm2 ua
|
Ω/km
|
Ω/km
|
µF/km
|
mH/km
|
Ω/km
|
Amps
|
||
| 3 | 35 | 0.868 | 1.113 | 0.16 | 0.625 | 0.196 | 119 | 103 | 132 |
| 3 | 50 | 0.641 | 0.822 | 0.17 | 0.604 | 0.190 | 140 | 122 | 158 |
| 3 | 70 | 0.443 | 0.568 | 0.2 | 0.571 | 0.179 | 171 | 150 | 196 |
| 3 | 95 | 0.32 | 0.411 | 0.22 | 0.551 | 0.173 | 203 | 179 | 236 |
| 3 | 120 | 0.253 | 0.325 | 0.24 | 0.533 | 0.167 | 232 | 205 | 273 |
| 3 | 150 | 0.206 | 0.265 | 0.25 | 0.522 | 0.164 | 260 | 231 | 309 |
| 3 | 185 | 0.164 | 0.211 | 0.28 | 0.510 | 0.160 | 294 | 262 | 355 |
| 3 | 240 | 0.125 | 0.161 | 0.31 | 0.496 | 0.156 | 340 | 305 | 415 |
| 3 | 300 | 0.1 | 0.129 | 0.33 | 0.484 | 0.152 | 384 | 346 | 475 |
| 3 | 400 | 0.778 | 0.101 | 0.37 | 0.473 | 0.149 | 438 | 398 | 552 |
| 3 | 500 | 0.0605 | 0.079 | 0.41 | 0.462 | 0.145 | 505 | 460 | 646 |
| 20 | 25 | 35 | 40 | 45 | 50 | 55 | 60 |
| 1.08 | 1.04 | 0.96 | 0.91 | 0.87 | 0.82 | 0.76 | 0.71 |
| 10 | 15 | 25 | 30 | 35 | 40 | 45 | 50 |
| 1.07 | 1.04 | 0.96 | 0.93 | 0.89 | 0.85 | 0.80 | 0.76 |
|
No.of Cores
|
Core Cross sectional Area
|
Max. rub nro ntawm tus neeg xyuas pib
|
Charging Tam sim no ib theem
|
Zero sequence impedance
|
Hluav taws xob Stress ntawm Conductor Screen
|
Kev ntsuas luv luv ntawm Phase conductor
|
| Tsis muaj. | mm² os | kN kev | Amps / Km | Ohms/Km | kV / hli | kA, sec |
| 3 | 35 | 1.75 | 0.64 | 2.27 | 3.7 | 3.1 |
| 3 | 50 | 2.5 | 0.68 | 1.98 | 3.5 | 4.5 |
| 3 | 70 | 3.5 | 0.8 | 1.73 | 3.4 | 6.2 |
| 3 | 95 | 4.75 | 0.88 | 1.57 | 3.2 | 8.5 |
| 3 | 120 | 6 | 0.96 | 1.49 | 3.1 | 10.7 |
| 3 | 150 | 7.5 | 1 | 1.42 | 3.1 | 13.4 |
| 3 | 185 | 9.25 | 1.12 | 1.37 | 3.0 | 16.5 |
| 3 | 240 | 12 | 1.24 | 1.32 | 2.9 | 21.4 |
| 3 | 300 | 15 | 1.32 | 1.29 | 2.9 | 26.8 |
| 3 | 400 | 20 | 1.48 | 1.26 | 2.8 | 35.5 |
| 3 | 500 | 25 | 1.64 | 1.24 | 2.7 | 44.7 |