12.7/22Kv tooj liab nruab nrab voltage cable, rwb thaiv tsev txheej cov ntaub ntawv muaj zoo hluav taws xob rwb thaiv tsev kev ua tau zoo thiab tshuaj stability. Nws tuaj yeem tswj hwm nws cov kev ua haujlwm rwb thaiv tsev hauv qhov kub thiab txias thiab muaj kev tiv thaiv zoo rau ultraviolet rays thiab ya raws. Lub thickness ntawm lub rwb thaiv tsev txheej yog tsim raws li qhov ntsuas hluav taws xob thiab siv ib puag ncig ntawm lub cable los xyuas kom meej tias nws yuav tsis ua rau hluav taws xob poob lossis xau hauv qhov hluav taws xob siab.
Min. installation kub: 0 degree
Ua haujlwm kub: -25 degree rau +90 degree
Daim ntawv thov
3 core tooj liab nruab nrab voltage cable muaj zog tiv thaiv kev puas tsuaj thiab hluav taws kub, thiab tsim nyog rau kev nyab xeeb hluav taws xob nyob rau hauv ib puag ncig nyuaj ntawm cov chaw tsim kho. Cov chaw tsim kho feem ntau siv cov cables los muab kev txhawb zog rau cov khoom siv hluav taws xob ib ntus.

Feature

• Tus neeg xyuas pib: Stranded Compacted Circular Copper conductor raws li AS / NZS 1125
• Conductor Screen: Extruded Semi-conductive compound
• Rwb thaiv tsev: XLPE
• Rwb thaiv tsev Screen: Extruded Semi-conductive compound
• Kev thaiv dej ntev: Dej thaiv daim kab xev hauv qab tooj liab npo (Yeem)
• Hlau Rwb thaiv tsev Screen: Copper Wire Screen + helically siv tooj liab daim kab xev (E / F tam sim no muaj peev xwm - Raws li yuav tsum tau)
• binder daim kab xev / sheath hla cov cores sib dhos
• Metallic Sheath: Lead Alloy (yeem)
• Txheej txheej: Extruded Polyvinyl Chloride, Xim: Dub
• Kev tiv thaiv kab tua kab: Polyamide Nylon (yeem)
(Lwm txheej: PVC + HDPE Composite Sheath los yog PVC + Nylon + HDPE (cov ntaub qhwv nrog cov khoom tiv thaiv kab mob) los yog LSZH Cov ntaub qhwv sab nrauv, thiab cov kev txwv yuav hloov raws li)
Daim ntawv pov thawj
12.7/22Kv 3 core tooj liab nruab nrab voltage cable yog SAA tau ntawv pov thawj, tshwj xeeb tshaj yog AS / NZS 1429.1, thiab lwm yam, los xyuas kom meej tias cov cable ua raws li Australian cov qauv, ua pov thawj tias cov cable ua tau raws li cov kev cai nruj raws li kev nyab xeeb, kev ua tau zoo thiab kav ntev.

Pob

Hoobkas

Dongguan Greater Wire & Cable Co., Ltd., nyob hauv Dongguan City, Guangdong xeev. Nws koom nrog R&D, kev tsim khoom, muag thiab kev saib xyuas, tsom mus rau ntau yam xov hlau thiab cables, thiab muab cov kev daws teeb meem rau kev tsim kho loj xws li tshav dav hlau, tsev kho mob, chaw tsim khoom, thiab tsev kawm ntawv hauv ntau thaj tsam thoob ntiaj teb. Nrog cov cuab yeej tsim khoom thiab cov txheej txheem, ua tiav cov cuab yeej ntsuas, thiab cov cuab yeej muaj zog, lub tuam txhab tau tsim sai sai tom qab xyoo ntawm kev ua haujlwm hnyav thiab kev txhawb nqa ntawm cov neeg siv khoom thoob ntiaj teb, thiab tau yeej lub koob npe nrov thiab kev lag luam hauv kev lag luam txawv teb chaws.
Case

Tus khub

FAQ
Q: Yuav ua li cas txheeb xyuas qhov kev ua tau zoo ntawm cov kab hluav taws xob hluav taws xob?
1. Kev txheeb xyuas cov khoom siv rwb thaiv tsev: Cov thermal rwb thaiv tsev kev ua tau zoo ntawm cov cables feem ntau yog ze rau lawv cov ntaub ntawv rwb thaiv tsev. Cov khoom siv thermal rwb thaiv tsev muaj xws li cross-linked polyethylene (XLPE), ethylene propylene roj hmab (EPR), polyvinyl chloride (PVC), thiab lwm yam. Cov ntaub ntawv no ruaj khov ntawm qhov kub thiab txias thiab muaj cov thermal rwb thaiv tsev zoo.
Cov khoom siv sheath: Cov khoom siv sab nraud kuj cuam tshuam rau kev ua haujlwm thermal rwb thaiv tsev. Piv txwv li, qee cov cables siv cov roj hmab silicone, fluoroplastics (xws li FEP, PTFE) thiab lwm yam khoom siv los muab kev ua haujlwm zoo thermal rwb thaiv tsev.
2. Kev ntsuas kub ntawm qhov ntsuas kub ntawm qhov ntsuas kub: Feem ntau, sab nraud ntawm lub cable yuav raug cim nrog qhov ntsuas kub ntawm qhov ntsuas kub, xws li 70 degree, 90 degree, 105 degree, thiab lwm yam. ntev ntawm qhov kub thiab txias. Qhov siab dua qhov ntsuas kub tsis kam, qhov zoo dua qhov thermal rwb thaiv tsev ua haujlwm. Qee cov cables yuav qhia txog lub sijhawm luv luv ntawm qhov kub thiab txias, xws li 250 degree, uas tuaj yeem pab txiav txim siab nws qhov kev ruaj ntseg nyob rau lub sij hawm luv luv.
3. Cov qauv tsim nyog thiab cov ntawv pov thawj: Cables uas ua tau raws li cov qauv thoob ntiaj teb feem ntau yog cim nrog lawv cov rwb thaiv tsev thiab cov qib ntsuas kub. Cov qauv no qhia txog kev ua haujlwm ntawm cov cables nyob rau hauv qhov kub thiab txias. Qee cov kab hluav taws xob muaj cov ntawv pov thawj tiv thaiv hluav taws, xws li UL fireproof mark lossis IEC test pass mark. Xws li cables feem ntau muaj kev rwb thaiv tsev zoo heev thiab hluav taws kub.
4. Kev sim txoj kev sim: Los ntawm kev muab cov cable tso rau hauv qhov kub thiab txias ib puag ncig rau qee lub sijhawm, kev soj ntsuam lub cev kev hloov pauv thiab kev hloov hluav taws xob ntawm cov txheej txheej rwb thaiv tsev, yog tias lub cable tuaj yeem ruaj khov, nws cov thermal rwb thaiv tsev kev ua tau zoo. Siv cov cuab yeej tshaj lij los ntsuas qhov thermal kuj coefficient ntawm cable. Cables uas tsis tshua muaj thermal kuj coefficients tuaj yeem cais cov cua sov zoo dua.
5. Rwb thaiv tsev thickness: Cables nrog thicker rwb thaiv tsev txheej feem ntau muaj ntau dua thermal rwb thaiv tsev kev ua tau zoo. Koj tuaj yeem tshawb xyuas cov rwb thaiv tsev tuab los ntawm kev sab laj cov lus qhia cable lossis txiav cov ntu ntu. Qee cov kab hluav taws xob hluav taws xob siab siv cov txheej txheem ntau txheej, xws li cov txheej txheem XLPE sab hauv ntxiv rau txheej PVC sheath, uas tuaj yeem txhim kho cov thermal rwb thaiv tsev zoo.
6. Thermal conductivity ntawm cov khoom siv: Qee cov khoom siv thermal rwb thaiv tsev muaj cov thermal conductivity tsis zoo, uas pab cais cov cua sov. Yog tias cov thermal conductivity ntawm cov khoom siv rwb thaiv tsev yog tsawg (xws li ceramic rwb thaiv tsev lossis silicone), ces nws cov thermal rwb thaiv tsev kev ua tau zoo yuav zoo dua.
7. Rated tam sim no nqa peev xwm: Lub peev xwm nqa tam sim no muaj feem xyuam nrog kev ua haujlwm thermal rwb thaiv tsev ntawm lub cable. Cables nrog zoo thermal rwb thaiv tsev kev ua tau zoo tuaj yeem tswj qhov kub sab nraud ntawm cov dej ntws siab dua.
Q: Kuv tuaj yeem tau txais tus qauv li cas?
Q: Koj puas txhawb OEM?
Hot Tags: 12.7 / 22kv 3 core tooj liab nruab nrab voltage cable, Tuam Tshoj 12.7 / 22kv 3 core tooj liab nruab nrab voltage cable manufacturers, lwm tus neeg, Hoobkas


|
Tsis muaj
Cores
|
Core Cross
ntu
Thaj tsam
|
Nominal Dia
|
||
|
Hauv qab
nws yog xim hlau
npo
|
Hauv qab
nws yog xim hlau
npo
|
Zuag qhia tag nrho
|
||
|
Tsis muaj.
|
mm2 ua
|
mm
|
mm
|
mm
|
| 3 | 35 | 21.1 | 22.6 | 54.0 |
| 3 | 50 | 22.2 | 23.7 | 57.0 |
| 3 | 70 | 23.9 | 25.4 | 60.0 |
| 3 | 95 | 25.4 | 26.9 | 64.0 |
| 3 | 120 | 27 | 28.5 | 67.0 |
| 3 | 150 | 28.4 | 29.9 | 71.0 |
| 3 | 185 | 30.1 | 31.6 | 75.0 |
| 3 | 240 | 32.4 | 33.9 | 80.0 |
| 3 | 300 | 34.4 | 35.9 | 84.0 |
| 3 | 400 | 37.2 | 38.7 | 91.0 |
| 3 | 500 | 40.6 | 42.1 | 99.0 |
|
No.of Cores
|
Core Cross sectional Area
|
Max. DC Resistance ntawm 20˚C
|
Max. AC Resistance ntawm 90˚C
|
Kwv yees li. Capacitance
|
Kwv yees li. Inductance
|
Kwv yees li.
Reactance |
Kev ntsuas tam sim no tsis tu ncua
|
||
| faus direet hauv av |
Nyob rau hauv ib tug faus duct
|
Hauv Cua
|
|||||||
|
Tsis muaj.
|
mm2 ua
|
Ω/km
|
Ω/km
|
µF/km
|
mH/km
|
Ω/km
|
Amps
|
||
| 3 | 35 | 0.524 | 0.668 | 0.16 | 0.625 | 0.196 | 153 | 133 | 170 |
| 3 | 50 | 0.387 | 0.494 | 0.17 | 0.604 | 0.190 | 181 | 158 | 204 |
| 3 | 70 | 0.268 | 0.342 | 0.2 | 0.569 | 0.179 | 221 | 193 | 253 |
| 3 | 95 | 0.193 | 0.246 | 0.22 | 0.551 | 0.173 | 262 | 231 | 304 |
| 3 | 120 | 0.153 | 0.196 | 0.24 | 0.533 | 0.167 | 298 | 264 | 351 |
| 3 | 150 | 0.124 | 0.159 | 0.26 | 0.521 | 0.164 | 334 | 297 | 398 |
| 3 | 185 | 0.0991 | 0.127 | 0.28 | 0.509 | 0.160 | 377 | 336 | 455 |
| 3 | 240 | 0.0754 | 0.097 | 0.31 | 0.496 | 0.156 | 434 | 390 | 531 |
| 3 | 300 | 0.0601 | 0.078 | 0.33 | 0.484 | 0.152 | 489 | 441 | 606 |
| 3 | 400 | 0.047 | 0.062 | 0.37 | 0.473 | 0.149 | 553 | 501 | 696 |
| 3 | 500 | 0.0366 | 0.049 | 0.41 | 0.462 | 0.145 | 632 | 574 | 800 |
| 20 | 25 | 35 | 40 | 45 | 50 | 55 | 60 |
| 1.08 | 1.04 | 0.96 | 0.91 | 0.87 | 0.82 | 0.76 | 0.71 |
| 10 | 15 | 25 | 30 | 35 | 40 | 45 | 50 |
| 1.07 | 1.04 | 0.96 | 0.93 | 0.89 | 0.85 | 0.80 | 0.76 |
|
No.of Cores
|
Core Cross sectional Area
|
Max. rub nro ntawm tus neeg xyuas pib
|
Charging Tam sim no ib theem
|
Zero sequence impedance
|
Hluav taws xob Stress ntawm Conductor Screen
|
Kev ntsuas luv luv ntawm Phase conductor
|
| Tsis muaj. | mm² os | kN kev | Amps / Km | Ohms/Km | kV / hli | kA, sec |
| 3 | 35 | 2.45 | 0.64 | 1.83 | 3.7 | 5.0 |
| 3 | 50 | 3.5 | 0.68 | 1.65 | 3.5 | 7.2 |
| 3 | 70 | 4.9 | 0.8 | 1.50 | 3.4 | 10.0 |
| 3 | 95 | 6.65 | 0.88 | 1.41 | 3.2 | 13.6 |
| 3 | 120 | 8.4 | 0.96 | 1.36 | 3.1 | 17.1 |
| 3 | 150 | 10.5 | 1.04 | 1.32 | 3.1 | 21.4 |
| 3 | 185 | 12.95 | 1.12 | 1.29 | 3.0 | 26.4 |
| 3 | 240 | 16.8 | 1.24 | 1.26 | 2.9 | 34.3 |
| 3 | 300 | 21 | 1.32 | 1.24 | 2.9 | 42.8 |
| 3 | 400 | 28 | 1.48 | 1.22 | 2.8 | 56.9 |