25 Mm² H07V-K Cable Rau Industrial Equipment Thiab Distribution Txee

25 Mm² H07V-K Cable Rau Industrial Equipment Thiab Distribution Txee
Details:
· Tus neeg xyuas pib: Chav kawm 5 hloov pauv tau tooj liab
· Rwb thaiv tsev: PVC (Polyvinyl Chloride)
Voltage Rating Uo/U: H05V-K: 300/500V ; H07V-K: 450/750V
· Kev ntsuas kub: Tsau: -30℃rau +70℃; Flexed: -5℃rau +70 degree
Cov qauv: EN 50525-2-31, EN 60228; Nplaim Retardant raws li IEC / EN 60332-1-2; UV Resistant
Send Inquiry
Download
Kev piav qhia
Technical Parameters
Daim ntawv pov thawj

H07V-K 25mm2 cable

PRODUCT REAL SHOT

 

H07V-K 25 mm2 wire
H07V-K 25mm2 cable
25mm2 H07V-K cable

25 sq mm H07V-K wire

Flexible 25 mm² Copper Wire rau kev tiv thaiv hluav taws xob khoom sib txuas
Cov cuab yeej siv khoom lag luam thiab cov khoom faib khoom yuav xav tau hnyav dua ib zaug -cov tub ntxhais cov neeg siv khoom thaum tseem tau txais txiaj ntsig los ntawm kev hloov pauv thaum lub sijhawm teeb tsa. H07V-K tuaj yeem ua haujlwm li25 mm² khoom siv fais fab hlaurau tsim kev tiv thaiv nyob rau hauv circuits ntawm switching devices, terminals thiab lub hwj chim Cheebtsam. Nws Chav Kawm 5 kev tsim kho kuj tseem ua rau nws muaj txiaj ntsig zoo li kev faib khoom txee hloov tau yooj yim uas cov neeg tsim khoom xav tau kev khoov yooj yim dua nrog cov neeg siv khoom nruj. GERITEL WIRE tuaj yeem pab txhawb kev xaiv xim, luam tawm cov cim, xa tawm ntim thiab cov ntaub ntawv kev tshuaj xyuas rau OEM cov haujlwm. Thaum tau teev tseg raws li kev lag luam davhlau ya nyob twg txuas hlau, tus tsim qauv yuav tsum paub meej tias muaj peev xwm tam sim no, lub log lossis lub davhlau ya nyob twg, qhov ntsuas kub thiab cov qauv siv tau.
PRODUCT SPECIFICATIONS

 

2491X H07V-K 25mm2 cable

Daim ntawv thov

 

PVC vaj huam sib luag thaiv siv rau hauv kev tswj kev hloov, relay thiab instrumentation panels ntawm lub hwj chim switchgear thiab rau lub hom phiaj xws li cov connectors nyob rau hauv cov khoom rectifier, lub cev muaj zog pib thiab controllers.

SPECIFICATIONS
Kev ntsuas voltage Uo / U

H05V-K:300/500V

H07V-K:450/750V

Kev ntsuas kub

Tsau: -30℃rau +70 degree

Flexed: -5℃rau +70 degree

Yam tsawg kawg Bending Radius Tsau: 6 x tag nrho txoj kab uas hla
Tus coj Class 5 hloov tau tooj liab conductor
Rwb thaiv tsev PVC (Polyvinyl Chloride)
Rwb thaiv tsev xim Liab, Dub, Xiav, Txiv kab ntxwv, Daj, Dawb, Ntsuab / Daj, Violet, Paj yeeb, Grey, Xim av
STANDARDS

EN 50525-2-31, EN 60228

Nplaim Retardant raws li IEC / EN 60332-1-2

UV Resistant

DIMENSION

NOMINAL CROSS SECTIONAL AREA

mm² os

NOMINAL ZAJ NKAUJ DIAMETER

mm² os

NOMINAL WEIGHT

kg/km

H05V-K
0.5 2.20 9.1
0.75 2.40 11.7
1 2.55 14.4
H07V-K
1.5 3.00 20.1
2.5 3.65 31.5
4 4.20 46.2
6 4.80 65.1
10 6.25 109.4
16 7.40 165.2
25 9.40 253.4
35 10.40 345.5
50 12.55 492.4
70 14.10 669.3
95 17.20 910.4
120 17.70 1129.4
150 19.60 1401.0
185 23.00 1741.0
240 26.40 2267.5

Cov kws qhia

NOMINAL CROSS

SIBAL UA

mm² os

MAXIMUM DIAMETER

NTAWM WIRES IN CONDUCTOR

mm

MAXIMUM RESISTANCE CONDUCTOR ntawm 20 degree

ohms/km

Plain Hlau
0.5 0.21 39
0.75 0.21 26
1 0.21 19.5
1.5 0.26 13.3
2.5 0.26 7.98
4 0.31 4.95
6 0.31 3.3
10 0.41 1.91
16 0.41 1.21
25 0.41 0.78
35 0.41 0.554
50 0.41 0.386
70 0.51 0.272
95 0.51 0.206
120 0.51 0.161
150 0.51 0.129
185 0.51 0.106
240 0.51 0.0801

ELECTRICAL CHARACTERISTICS

NOMINAL CROSSS

ECTIONAL AREA

mm² os

CEEB TOOM A

(XAIV IN

CONDUIT IN THERMALLY

Insulating WALL ETC)

Amps

CEEB TOOM B

(TSIS TXAUS SIAB RAU HAUV CONduIT

HAUV VAJTSWV LUB SIJ HAWM

TRUNKING ETC)
Amps

CEEB TOOM C

(CLIPPED DIRECT)
Amps

CEEB TOOM F

(Nyob hauv huab cua dawb lossis ONA PERFORATED CABLE TRAY ETC HORIZONTAL lossis VERTICAL ETC)

Amps

Kov

Spaced los ntawm

ib diam

2 Cables Ib -Phase ACor DC lossis 3 Cables Peb-Phase AC tiaj tus

2 Kab

Tib -Phase

ACor DC

3o4 kab

Peb -Phase

AC

2 Kab

Tib -Phase

ACor DC

3o4 kab

Peb -Phase

AC

2 Kab

Tib -Phase

AC lub DC

3o4 ibCables

Peb -Theem

AC

2 Kab

SinglePhase

AC lub DCtiaj tus

3 Kab

Peb -Phase

ACflat

3 kab

Peb -Phase

ACtrefoil cov khoom

Kab rov tav Ntsug
1.5 14.5 13.5 17.5 15.5 20 18 - - - - -
2.5 20 18 24 21 27 25 - - - - -
4 26 24 32 28 37 33 - - - - -
6 34 31 41 36 47 43 - - - - -
10 46 42 57 50 65 59 - - - - -
16 61 56 76 68 87 79 - - - - -
25 80 73 101 89 114 104 131 114 110 146 130
35 99 89 125 110 141 129 162 143 137 181 162
50 119 108 151 134 182 167 196 174 167 219 192
70 151 136 192 171 234 214 251 225 216 281 254
95 182 164 232 207 284 261 304 275 264 341 311
120 210 188 269 239 330 303 352 321 308 396 362
150 240 216 300 262 381 349 406 372 356 456 419
185 273 245 341 296 436 400 463 427 409 521 480
240 321 286 400 346 515 472 546 507 485 615 569
CERTIFICATIONS

 

2491X 25mm2 cable

H07VK 25mm2 wire

Ntim

 

07V-K 25mm2 cable

Yob

25mm2 flexible panel wire

Yas Reel

25mm2 panel wire

Ntoo Ntoo Reel

APPLICATION

 

25mm2 single core flexible cable
Industrial Control Vaj Huam Sib Luag
25mm2 PVC single core wire
Kev Txuas Txuas Hluav Taws Xob Hluav Taws Xob
25mm2 Class 5 flexible wire

Switchboard thaiv kab

 

CAS

 

25mm2 flexible copper wire

Adelaide Tshav Dav Hlau Switchboard Upgrade

25mm2 control cabinet wire

Industrial Main Switchboard Fais Fab Distribution

25mm2 equipment wire

Main Switchboard Flexible Cable Hloov

Vim li cas thiaj xaiv peb

 

30Xyoo ntawm kev paub
hauv ib qho - nres kev pabcuam

Dongguan Greater Wire & Cable Co., Ltd. yog tus kws tshaj lij engineering- qib cable chaw tsim khoom hauv Suav teb, muab cov ntawv pov thawj hluav taws xob cable daws teeb meem rau lub tsev, kev lag luam, tsuas, hluav taws xob, thiab kev tsim kho vaj tse thoob ntiaj teb.

Nrog rau 30,000 m² Hoobkas, 30 cov kab ntau lawm, cov kws tshaj lij engineers, thiab pab pawg tswj xyuas nruj, peb muab cov khoom lag luam txhim khu kev qha, traceable, thiab ua raws cov khoom siv cable rau kev siv engineering thoob ntiaj teb. Peb cov khoom tau txais kev txhawb nqa los ntawm cov ntawv pov thawj suav nrog SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, thiab ISO.

Peb tau cog lus rau kev nyab xeeb, kev ua tau zoo, pob tshab, thiab kev sib koom ua ke ntev -. Los ntawm kev tshuaj xyuas cov khoom siv raw mus rau kev kuaj cov khoom tiav, txhua batch yog ua tib zoo tswj xyuas kom ruaj khov kev ua tau zoo thiab siv tau qhov project.

Greater Cable - Certified Quality. Kev ntseeg tau. Engineering tus nqi.

25mm2 450/750V flexible cable
 
15K
Kev Ua Haujlwm tiav
150+
cov neeg ua haujlwm tshaj lij
15K
zoo siab cov neeg siv khoom
92+
khoom plig & certifacates
COV TSWV YIM

 

H07V-K 25mm2 datasheet
 
H07V-K 25mm2 current rating
 
H07V-K 25mm2 amp rating
 
H07V-K 25mm2 current carrying capacity
 
H07V-K 25mm2 conductor resistance
 
H07V-K 25mm2 cable diameter
 
GLOBAL CERTIFICATIONS

 

H07V-K 25mm2 cable weight

COV PHOOJ YWG
 

EN 50525-2-31 25mm2 cable

INTERNATIONL TRANSPORTATION

 

01

Hiav txwv Freight

Peb muab cov kev daws teeb meem hauv hiav txwv txhim khu kev qha rau loj - ntim xaj. Koj cov khoom tau ntim khoom ruaj ntseg thiab xa mus rau hauv cov thawv ntim khoom, xyuas kom tus nqi - xa mus rau cov chaw nres nkoj thoob ntiaj teb.

02

Cua Freight

Rau kev xa khoom sai, peb cov kev pabcuam huab cua ua kom koj cov khoom mus txog thoob ntiaj teb cov chaw sai sai, nrog kev ceev faj thiab taug qab tag nrho ntawm txoj kev.

03

International Express

Xav tau kev thauj mus los sai? Peb cov kev pabcuam nthuav qhia thoob ntiaj teb muab kev txiav txim me me mus rau nruab nrab kom tau txais txiaj ntsig zoo, muab lub qhov rooj - mus rau - qhov rooj pabcuam nrog - lub sijhawm taug qab kom muaj kev thaj yeeb nyab xeeb.

IEC 60228 Class 5 25mm2 wire
COOPERATIVE PARTNER

 

Peb tab tom nrhiav kev sib koom tes los nthuav peb txoj kev lag luam.

H07V-K 25mm2 technical specification
25mm2 switchgear internal wire
25mm2 distribution panel wire
25mm2 motor control panel wire
25mm2 machine control cabinet wire
25mm2 building conduit wire
25mm2 switchboard wire
25mm2 control panel power wire
25mm2 EV charger cabinet wire
25mm2 energy storage cabinet wire
Yuav koom tes nrog peb li cas?

Tsuas qhia koj cov kev xav tau, tau txais peb cov kev daws teeb meem, paub meej cov qauv, thiab txaus siab rau kev tsim khoom sai, txhim khu kev qha thiab xa khoom thoob ntiaj teb - ua haujlwm nrog peb yog qhov yooj yim.

Peb qhov chaw nyob

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Suav teb

Xov tooj

+86 136 6257 9592

+86 135 1078 4550

E -mail

manager01@greaterwire.com

25mm2 data center earthing wire
FAQ

 

Puas muaj xim H07V-K siv los tiv thaiv lub ntiaj teb?
Tiv thaiv lub ntiaj teb conductor ximyog tswj nyob rau hauv ntau lub khw, nrog ntsuab / daj ib txwm tseg rau PE. Tsis txhob xaiv cov xim arbitrary tsuas yog vim tias cov khoom hluav taws xob zoo ib yam. Rau cov kev pab cuam ntev -, GERITEL WIRE tuaj yeem tswj xyuas cov cim xim zoo ib yam, daim ntawv lo thiab cov ntaub ntawv xaj kom txo tau qhov tsis tuaj yeem tau txais thiab kev sib dhos yuam kev.
Yuav ua li cas kuv loj H07V-K rau earthing?
Kev tiv thaiv lub ntiaj teb cable sizing yog nyob ntawm tus qauv siv txuas, txhaum tam sim no, lub sijhawm sib txuas, cuam tshuam rau theem tus neeg xyuas pib thiab cov khoom tsim. Tsis txhob xaiv PE tus neeg xyuas pib tsuas yog los ntawm cov khoom thauj tam sim no. GERITEL WIRE tuaj yeem tshuaj xyuas tus neeg yuav khoom daim duab, lub luag haujlwm hauv Circuit Court thiab lub hom phiaj ua lag luam ua ntej hais, pab tiv thaiv tus qauv tsis sib haum ua ntej tsim khoom.
H07V-K puas tuaj yeem siv los ua kev sib txuas ntawm cov hlua hluav taws xob?
Ib qho kev sib txuas yooj yim jumper xaim tuaj yeem siv rau kev sib txuas equipotential qhov tau tso cai, tab sis cov kev xav tau ntawm lub tais sib txawv ntawm cov kab ke ib txwm muaj. Ua raws li tus qauv kev teeb tsa thiab siv cov lugs pom zoo lossis cov khoom siv sib txuas. Rau OEM tej yaam num, GERITEL WIRE tuaj yeem koom tes nrog cov sijhawm xim, cov khoom cim, reel lossis lub thawv ntim khoom thiab xa tawm cov ntaub ntawv nyob ib ncig ntawm qhov kev pom zoo kawg.
Puas yog lub ntiaj teb hloov tau zoo dua li cov hlau hauv ntiaj teb?
Lub ntiaj teb hloov pauv tus neeg xyuas pib yooj yim dua rau txoj hauv kev ncig lub qhov rooj, thav duab thiab cov khoom siv sib txuas, thaum cov khoom siv lossis Class 2 tus neeg xyuas pib yuav nyiam nyob rau hauv lwm qhov kev teeb tsa. Qhov kev xaiv raug yog nyob ntawm cov txheej txheem tshuab thiab cov txheej txheem tswj. GERITEL WIRE txhawb nqa kev qhia meej thiab cov qauv kev pom zoo, uas yog qhov muaj txiaj ntsig zoo thaum lub vaj huam sib luag tsim yuav tsum tau kuaj xyuas stripping, routing lossis davhlau ya nyob twg ua ntej kev txiav txim ntau.

 

Hot Tags: 25 mm² h07v-k cable rau cov khoom siv thiab cov khoom xa tawm, Tuam Tshoj 25 mm² h07v-k cable rau cov khoom siv thiab cov khoom faib khoom lag luam, cov chaw muag khoom, lub Hoobkas

Send Inquiry