Hnub Ci System Cable Rau Hnub Ci Arrays Thiab Inverter Txuas

Hnub Ci System Cable Rau Hnub Ci Arrays Thiab Inverter Txuas
Details:
Tus neeg xyuas pib: Electrolytic annealed tinned tooj liab, chav kawm 5 (hloov tau) raws li IEC 60228 thiab EN 60228.
· Rwb thaiv tsev: Halogen dawb cross- txuas roj hmab raws li cov lus B1 hauv Annex B ntawm EN 50618 thiab IEC 62930.
· Cov ntaub qhwv sab nraud: Halogen tsis pub hla- txuas cov roj hmab hloov tau raws li cov lus B1 hauv Annex B ntawm EN 50618 thiab IEC 62930.Liab lossis xim dub.
Cov hluav taws xob qis:: 1.5 (1,8) kV DC . 1, 0/1,0 kV AC.
Send Inquiry
Download
Kev piav qhia
Technical Parameters
Daim ntawv pov thawj

 

TÜV solar cable for rural communication solar system

PRODUCT REAL SHOT

 

photovoltaic cable for rural communication solar system
solar array cable for rural communication solar system
off grid telecom microgrid solar cable

off grid telecom microgrid PV cable

PV DC Fais Fab Cable - Ua rau Slexible thiab Durable Solar Installation
Nplooj ntawv no GERITEL WIRE tsom rau lub hnub ci kev sib koom ua ke nrhiav kev vam khom photovoltaic thaiv hauv vaj huam sib luag, hlua, sib txuas thiab inverter DC thaiv, nrog rau kev tsom mus rau pv system thaiv. Nplooj ntawv ib txwm tsomhnub ci hluav taws xob cablethiab photovoltaic system xaim, ob nqe lus neeg yuav khoom feem ntau cuam tshuam nrog kev xaiv hnub ci cable thiab qhov project nrhiav. Kev tsim kho ua ke ua ke zoo -Txais Chav Kawm 5 tinned tooj liab nrog halogen-dawb ntoo khaub lig- txuas rwb thaiv tsev thiab cov ntaub ntawv sheath rau saj zawg zog, sab nraum zoov- taw qhia txog kev xaim hluav taws xob photovoltaic. Nws qhov kev ua tau zoo profile yog tsom rau ntev - lub hnub ci kev teeb tsa qhov chaw tshav kub, tshav ntuj, av noo thiab huab cua tiv thaiv yog qhov tseem ceeb ntawm kev xaiv. GERITEL WIRE tuaj yeem pab txhawb OEM kos npe, ntim qhov project, cov ntaub ntawv thev naus laus zis thiab xa tawm- taw qhia cov khoom lag luam rau cov neeg xa khoom thiab EPC cov neeg yuav khoom.
PRODUCT SPECIFICATIONS

 

TÜV solar cable for off grid telecom microgrid

Daim ntawv thov

 

GERITEL WIRE PV H1Z2Z2-K cable, uas yog TUV tau ntawv pov thawj raws li EN 50618 thiab AENOR tau ntawv pov thawj raws li IEC62930, nws yog qhov tsim nyog rau ob qho tib si tsau thiab txawb hnub ci kev teeb tsa (hnub ci ua liaj ua teb, lub hnub ci ntsa iab thiab cov nroj tsuag ntab). vaj huam sib luag.

Qhov ntau yam no ib leeg -conductor cable yog tsim los ua kom tau raws li qhov sib txawv ntawm kev lag luam hnub ci.

Haum rau qhov chaw ntub dej, ntub thiab ntub.

Hnub ci PV installation hlua cable.

SPECIFICATIONS
Tus coj Electrolytic annealed tinned tooj liab, chav kawm 5 (hloov tau) raws li IEC 60228 thiab EN 60228.
Rwb thaiv tsev Halogen dawb hla- txuas roj hmab raws li rooj B1 hauv Annex Bof EN 50618 thiab IEC 62930.
Sab nrauv

Halogen tsis pub hla- txuas cov roj hmab hloov tau raws li cov lus B1 hauv Annex B ntawm EN 50618 thiab IEC 62930.

Liab los yog xim dub.

Kev ua haujlwm hluav taws xob

Tsawg voltage: 1.5 (1.8) kV DC.

1.0/1.0 kV AC

Kev ua haujlwm thermal Qhov ntsuas kub siab tshaj plaws: 90℃(120℃thaum lub sijhawm 20.000 h). Qhov siab tshaj plaws luv luv-circuit kub: 250℃(max. 5 s). Qhov kev pabcuam kub: -40℃(tso thiab tiv thaiv kev teeb tsa).
Hluav taws ua haujlwm

Cov nplaim hluav taws tsis yog{0}} nthuav tawm raws li EN 60332-1-2 / IEC 60332-1-2.

Hluav taws kub tsis- nthuav tawm raws li EN 50399.Reaction rau hluav taws CPR: Caa-slb, d2, al raws li EN 50575.Low pa luam yeeb halogen dawb raws li EN 60754-1 / IEC 60754-1.Low corrosive raws li 40 EN 205 gasees IEC 60754-2.

Cov pa luam yeeb tsawg raws li EN 61034 / IEC 61034:

Lub teeb transmittance> 60%.

Mechanical kev ua tau zoo

Yam tsawg kawg bending radius:

4x cable txoj kab uas hla (kab txoj kab uas hla Tsawg dua los yog sib npaug li 8 hli)

5 x cable txoj kab uas hla (8 < cable inch s 12 mm)

6x cable diameter (cable diameter >12 mm).

Impact resistance: AG2 Nruab nrab hnyav.

Kev ua haujlwm ib puag ncig

Tshuaj & Roj kuj: Zoo heev.

Roj & ntxhia roj tsis kam: Zoo heev.

Ozone resistant raws li EN 50618.

UV Resistant raws li EN 50618 thiab IEC 62930.

Dej tsis kam: AD 7+ Immersion.

AD8 Submersion.

Installation tej yam kev mob Qhib Cua.
faus.
Hauv cov kav dej.
Tus coj Tus coj
Stranding
Rwb thaiv tsev
Thickness
Jacket Thickness Nominal
O.D.
Kwv yees li Net nyhav Kev tso cai muaj peev xwm (1)
@30℃Ambient
 

Nominal

Thaj chaw(mm2)

Number of Strands mils mils Ntiv lbs / 1000 ft 75 degree 90 degree  
1X1.5 1.57 0.7 0.8 4.7 38 860 0.86 13.7
1X2.5 2.04 0.7 0.8 5.2 45 690 0.69 8.21
1X4 2.6 0.7 0.8 5.6 60 580 0.58 5.09
1X6 3.16 0.7 0.8 6.3 90 500 0.50 3.39
1X10 4.5 0.7 0.8 7.6 131 420 0.42 1.95
1X16 5.7 0.7 0.9 9.0 187 340 0.34 1.24
1X25 7.2 0.9 1.0 11.2 267 340 0.34 0.795
1X35 8.5 0.9 1.1 12.7 368 290 0.29 0.565
1X50 9.4 1.0 1.2 14.5 560 270 0.27 0.393
1X70 11.1 1.1 1.2 16.5 756 250 0.25 0.277
1X95 13.1 1.1 1.3 18.7 1036 220 0.22 0.210
1X120 14.8 1.2 1.3 20.4 1309 210 0.21 0.164
1X150 16.5 1.4 1.4 22.7 1636 210 0.21 0.132
1X185 18.3 1.6 1.6 25.2 2000 200 0.20 0.108
1X240 21.0 1.7 1.7 28.5 2607 200 0.20 0.0817
2X1.5 1.57 0.7 0.8 4.8*10.5 78 860 0.86 13.7
2X2.5 2.04 0.7 0.8 5.2*11.8 92 690 0.69 8.21
2X4 2.6 0.7 0.8 5.6*12.8 122 580 0.58 5.09
2X6 3.16 0.7 0.8 6.3*13.7 182 500 0.50 3.39
2X10 4.5 0.7 0.8 8.0*16.8 264 420 0.42 1.95
2X16 5.7 0.7 0.9 9.0*19.8 376 340 0.34 1.24
 
CERTIFICATIONS

 

photovoltaic cable for off grid telecom microgrid

Ntim

 

solar array cable for off grid telecom microgrid

1, Roll

agrivoltaic system solar cable

Ntoo Ntoo Reel

agrivoltaic system PV cable

Loj Ntoo Reel

APPLICATION

 

TÜV solar cable for agrivoltaic system
Residential Rooftop Solar System
H1Z2Z2-K cable for agrivoltaic system
Hnub Ci Carport + EV Charging
photovoltaic wiring for agrivoltaic system
Kev siv hluav taws xob-Sale Solar Far
CAS

 

solar greenhouse solar cable

Mauritius Henrietta Hnub Ci Fais Fab Cog Hlau Hlau Export

solar greenhouse PV cable

Somalia Mogadishu Solar PV System Project

TÜV solar cable for solar greenhouse

Tunisia Hammamet Tshiab Lub Nroog Industrial Park Hnub Ci PV Project

Vim li cas thiaj xaiv peb

 

30Xyoo ntawm kev paub
hauv ib qho - nres kev pabcuam

Dongguan Greater Wire & Cable Co., Ltd. yog tus kws tshaj lij engineering- qib cable chaw tsim khoom hauv Suav teb, muab cov ntawv pov thawj hluav taws xob cable daws teeb meem rau lub tsev, kev lag luam, tsuas, hluav taws xob, thiab kev tsim kho vaj tse thoob ntiaj teb.

Nrog rau 30,000 m² Hoobkas, 30 cov kab ntau lawm, cov kws tshaj lij engineers, thiab pab pawg tswj xyuas nruj, peb muab cov khoom lag luam txhim khu kev qha, traceable, thiab ua raws cov khoom siv cable rau kev siv engineering thoob ntiaj teb. Peb cov khoom tau txais kev txhawb nqa los ntawm cov ntawv pov thawj suav nrog SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, thiab ISO.

Peb tau cog lus rau kev nyab xeeb, kev ua tau zoo, pob tshab, thiab kev sib koom ua ke ntev -. Los ntawm kev tshuaj xyuas cov khoom siv raw mus rau kev kuaj cov khoom tiav, txhua batch yog ua tib zoo tswj xyuas kom ruaj khov kev ua tau zoo thiab siv tau qhov project.

Greater Cable - Certified Quality. Kev ntseeg tau. Engineering tus nqi.

H1Z2Z2-K cable for solar greenhouse
 
15K
Kev Ua Haujlwm tiav
150+
cov neeg ua haujlwm tshaj lij
15K
zoo siab cov neeg siv khoom
92+
khoom plig & certifacates
COV TSWV YIM

 

photovoltaic wiring for solar greenhouse
 
solar irrigation system solar cable
 
solar irrigation system PV cable
 
TÜV solar cable for solar irrigation system
 
H1Z2Z2-K cable for solar irrigation system
 
photovoltaic wiring for solar irrigation system
 
GLOBAL CERTIFICATIONS

 

solar water pumping system solar cable

COV LUS DUAB
 

solar water pumping system PV cable

INTERNATIONL TRANSPORTATION

 

01

Hiav txwv Freight

Peb muab cov kev daws teeb meem hauv hiav txwv txhim khu kev qha rau loj - ntim xaj. Koj cov khoom tau ntim khoom ruaj ntseg thiab xa mus rau hauv cov thawv ntim khoom, xyuas kom tus nqi - xa mus rau cov chaw nres nkoj thoob ntiaj teb.

02

Cua Freight

Rau kev xa khoom sai, peb cov kev pabcuam huab cua ua kom koj cov khoom mus txog thoob ntiaj teb cov chaw sai sai, nrog kev ceev faj thiab taug qab tag nrho ntawm txoj kev.

03

International Express

Xav tau kev thauj mus los sai? Peb cov kev pabcuam nthuav qhia thoob ntiaj teb xa cov xaj me me mus rau nruab nrab kom tau txais txiaj ntsig zoo, muab lub qhov rooj - rau - qhov rooj pabcuam nrog - lub sijhawm taug qab kom muaj kev thaj yeeb nyab xeeb.

TÜV solar cable for solar water pumping system
COOPERATIVE PARTNER

 

Peb tab tom nrhiav kev sib koom tes los nthuav peb txoj kev lag luam.

H1Z2Z2-K cable for solar water pumping system
photovoltaic wiring for solar water pumping system
floating solar plant solar cable
floating solar plant PV cable
TÜV solar cable for floating solar plant
H1Z2Z2-K cable for floating solar plant
photovoltaic wiring for floating solar plant
floating PV system solar cable
floating PV system PV cable
TÜV solar cable for floating PV system
Yuav koom tes nrog peb li cas?

Tsuas qhia koj cov kev xav tau, tau txais peb cov kev daws teeb meem, paub meej cov qauv, thiab txaus siab rau kev tsim khoom sai, txhim khu kev qha thiab xa khoom thoob ntiaj teb - ua haujlwm nrog peb yog qhov yooj yim.

Peb qhov chaw nyob

Building 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Suav teb

Xov tooj

+86 136 6257 9592

+86 135 1078 4550

E -mail

manager01@greaterwire.com

H1Z2Z2-K cable for floating PV system
FAQ

 

Qhov kev pab cuam qhov kub thiab txias yog dab tsi?
Cov kev qhia tshwj xeeb uas tau muab teev tseg -40℃raws li qhov ntsuas kub tsawg kawg nkaus rau kev txhim kho / tiv thaiv. A -40℃hnub ci cable tseem xav tau kev tuav kom raug thaum lub sijhawm teeb tsa vim tias qhov ntsuas qhov ntsuas qhov tsawg kawg nkaus tuaj yeem sib txawv ntawm qhov ntsuas kub ruaj khov. GERITEL WIRE tuaj yeem pab kom paub meej tias tus qauv thov, qhov loj me, xim thiab kos npe ua ntej hais kom cov cable sib phim rau qhov project specification.
Kuv puas tuaj yeem nruab lub cable hauv qab khov?
Cov huab cua txias PV cable tuaj yeem ua haujlwm hauv qhov kub tsis tshua muaj, tab sis khoov thiab tuav cov kab mob khaub thuas yuav xav tau qhov ntsuas kub qis tshaj qhov ntsuas kub ntawm nws qhov ruaj khov - kev pabcuam. Tsis txhob yuam kom nruj nruj thaum lub cable txias heev. Rau qhov kev txiav txim, GERITEL WIRE tuaj yeem txhawb nqa kev qhia meej, kos npe cable, reel lossis nruas ntim thiab cov ntaub ntawv xa tawm.
4mm² hnub ci cable nqa tau npaum li cas?
Tsis muaj ib leeg4mm² hnub ci cable amp ntsuasuas siv rau txhua qhov kev teeb tsa. Tso cai tam sim no nyob ntawm tus neeg xyuas pib qhov kub thiab txias, ambient tej yam kev mob, pab pawg, routing thiab cov txheej txheem siv tau; voltage poob tej zaum yuav xav tau upsizing txawm ua ntej thermal tam sim no muaj peev xwm mus txog. GERITEL WIRE tuaj yeem tshuaj xyuas tus neeg yuav khoom qhov hluav taws xob, txoj kev ntev, qhov chaw tam sim no thiab kev teeb tsa ua ntej pom zoo rau qhov tsim nyog cable loj.
6mm² hnub ci cable nqa tau npaum li cas?
A 6mm² hnub ci cable tam sim no nyob ntawm txoj kev teeb tsa thiab cov cua sov, tsis yog tus ntoo khaub lig- ntu. Rau kev ua haujlwm ntev, qhov poob qis feem ntau yog vim li cas cov neeg tsim qauv xaiv 6mm² tsis yog 4mm². Rau cov neeg xa khoom thiab EPC cov neeg yuav khoom, GERITEL WIRE tuaj yeem muab kev lees paub tshwj xeeb, kev ntim khoom thiab cov ntaub ntawv txhawb nqa.

 

Hot Tags: Tuam Tshoj solar system cable rau hnub ci arrays thiab inverter txuas, Tuam Tshoj hnub ci system cable rau hnub ci arrays thiab inverter txuas manufacturers, lwm tus neeg, Hoobkas

Send Inquiry