Tus neeg xyuas pib:tooj liab conductor
Rwb thaiv tsev:XLPE rwb thaiv tsev
Filler:Taped los yog extruded txaj
Sheath:PVC hnab
Qhov kub thiab txias:-35 degree mus txog 90 degree
Rated voltage Uo / U:0.6/1 kV
Test voltage:4 (AC) kV
Txheem:VDE 0276-603 / HD 603 S1 / IEC 60502
Daim ntawv thov
N2XY cables yog tsim los txhim kho kev teeb tsa hauv ntau qhov chaw, suav nrog cov chaw sab hauv tsev thiab sab nraum zoov, nrog rau hauv av thiab hauv pob zeb. Cov kab hluav taws xob no tsim nyog siv rau hauv ob qho tib si hauv tsev thiab kev lag luam kev siv, muab lub zog txhim khu kev qha thiab tswj kev sib kis hauv cov kab hluav taws xob ruaj khov. Lawv muaj qhov ruaj khov PVC sheathing, muab kev tiv thaiv ib puag ncig xws li ya raws, tshuaj, thiab kev puas tsuaj rau lub cev.

Feature

N2XY cables yog tooj liab conductors uas muab kev ua tau zoo thiab kev ntseeg siab hauv kev xa hluav taws xob. Cov cables yog insulated nrog XLPE (cross-linked polyethylene) rau kev rwb thaiv tsev hluav taws xob zoo thiab ua kom sov, ua rau lawv haum rau ntau qhov chaw. Rau kev tiv thaiv ntxiv, cov cables tau nruab nrog daim kab xev los yog cov ntaub pua plag extruded kom ntseeg tau tias muaj zog thiab kev tiv thaiv tus neeg xyuas pib. Lub tsho PVC muab cov txheej txheej ruaj khov uas tiv thaiv cov kab hluav taws xob los ntawm cov khoom sab nraud, muab kev tiv thaiv rau ya raws, tshuaj lom neeg thiab puas.
Daim ntawv pov thawj
Peb cov khoom tau dhau UL, SAA, TUV, VDE, CE, CB thiab lwm yam ntawv pov thawj. Peb lub tuam txhab muaj cov ntawv pov thawj zoo rau txhua cheeb tsam. Peb muaj ntau tshaj 10 xyoo ntawm kev paub nyob rau hauv txawv teb chaws kev lag luam export, exporting rau ntau tshaj 90 lub teb chaws nyob ib ncig ntawm lub ntiaj teb no, thiab paub txog cov hlau thiab cable specifications thiab cov qauv ntawm ntau lub teb chaws.

Pob

Cov kab ntau lawm

Dongguan Greater Wire & Cable Co., Ltd. yog tsim nyob rau hauv 1995, nws yog ib tug kws tshaj lij hlau thiab cable chaw tsim tshuaj paus. Peb lub tuam txhab muaj cov cuab yeej siv ntau lawm thiab cov cuab yeej tsim khoom, ua tiav cov khoom siv, thiab cov khoom siv tshuab muaj zog. Tom qab xyoo ntawm kev ua haujlwm hnyav thiab kev txhawb nqa ntawm cov neeg siv khoom los ntawm thoob plaws lub ntiaj teb, peb lub tuam txhab tau tsim kho sai thiab yeej muaj kev hwm thiab koom nrog kev lag luam txawv teb chaws. Lub tuam txhab tau dhau ls09001 kev tswj hwm kev ua haujlwm tau ntawv pov thawj, National high tech enterprise certification, national specialization, and special new enterprise certification.
cov neeg siv khoom
Raws li cov chaw tsim khoom siv hlau thiab cable nrog ntau tshaj 10 xyoo ntawm kev xa tawm, peb pab cov neeg siv khoom thoob ntiaj teb thiab paub txog cov qauv xaim thiab cable hauv ntau lub teb chaws. Nrog cov neeg ua haujlwm thiab cov kws tsim hluav taws xob hauv ntau thaj tsam, peb ua kom muaj kev txhawb nqa hauv zos thiab kev txawj ntse.

Tus khub

FAQ
Q: N2XY yog dab tsi?
Q: Dab tsi yog xyov cable?
Cim npe nrov: Tuam Tshoj n2xy cable manufacturers, lwm tus neeg, Hoobkas

| No. ntawm cores thiab cross-section | Tus neeg xyuas pib | Txoj kab uas hla (qhov siab) ntawm tus neeg xyuas pib | Thickness - nominal rwb thaiv tsev | Thickness - nominal sheath | Txoj kab uas hla | Nyhav qhia | Yam tsawg kawg nkaus ntawm qhov khoov | Max. tso cai rub lub zog |
| mm² os | mm | mm | mm | mm | kg/km | mm | N | |
| 1*16 | RE | 4.4 | 0.7 | 1.8 | 10 | 220 | 147 | 800 |
|
1*25 |
RMV | 5.9 | 0.9 | 1.8 | 12 | 326 | 176 | 1250 |
|
1*35 |
RMV | 7.0 | 0.9 | 1.8 | 13 | 423 | 192 | 1750 |
| 1*50 | RMV | 8.2 | 1.0 | 1.8 | 14 | 550 | 213 | 2500 |
| 1*70 | RMV | 10.0 | 1.1 | 1.8 | 16 | 759 | 243 | 3500 |
| 1*95 | RMV | 11.7 | 1.1 | 1.8 | 18 | 1010 | 269 | 4750 |
| 1*120 | RMV | 13.2 | 1.2 | 1.8 | 20 | 1249 | 294 | 6000 |
| 1*150 | RMV | 14.6 | 1.4 | 1.8 | 22 | 1509 | 323 | 7500 |
| 1*185 | RMV | 16.4 | 1.6 | 1.8 | 24 | 1865 | 356 | 9250 |
| 1*240 | RMV | 18.6 | 1.7 | 1.8 | 26 | 2400 | 392 | 12000 |
| 1*300 | RMV | 21.1 | 1.8 | 1.8 | 29 | 2972 | 432 | 15000 |
| 1*400 | RMV | 24.2 | 2.0 | 1.9 | 33 | 3778 | 488 | 20000 |
| 1*500 | RMV | 27.3 | 2.2 | 2.0 | 36 | 4810 | 543 | 25000 |
| 4*16 | RE | 4.4 | 0.7 | 1.8 | 20 | 915 | 242 | 3200 |
| 4*25 | RMV | 5.9 | 0.9 | 1.8 | 25 | 1395 | 296 | 5000 |
| 4*35 | SM | 6.3 | 0.9 | 1.8 | 25 | 1631 | 295 | 7000 |
| 4*50 | SM | 7.3 | 1.0 | 1.9 | 26 | 2051 | 312 | 10000 |
| 4*70 | SM | 9.0 | 1.1 | 2.0 | 31 | 2881 | 366 | 14000 |
| 4*95 | SM | 10.6 | 1.1 | 2.1 | 34 | 3896 | 412 | 19000 |
| 4*120 | SM | 11.8 | 1.2 | 2.3 | 38 | 4873 | 454 | 24000 |
| 4*150 | SM | 13.4 | 1.4 | 2.4 | 43 | 6010 | 510 | 30000 |
| 4*185 | SM | 15.1 | 1.6 | 2.6 | 48 | 7489 | 572 | 37000 |
| 4*240 | SM | 17.4 | 1.7 | 2.8 | 54 | 9732 | 644 | 48000 |
| 5*16 | RE | 4.4 | 0.7 | 1.8 | 22 | 1122 | 263 | 4000 |
| 5*25 | RMV | 5.9 | 0.9 | 1.8 | 27 | 1749 | 324 | 6250 |
| 5*35 | RMV | 7.0 | 0.9 | 1.8 | 30 | 2299 | 360 | 8750 |
| 5*50 | SM | 7.9 | 1.0 | 2.0 | 30 | 2617 | 362 | 12500 |
| 5*70 | SM | 9.7 | 1.1 | 2.1 | 35 | 3665 | 425 | 17500 |
| 5*95 | SM | 11.0 | 1.1 | 2.3 | 39 | 4924 | 469 | 23750 |
| 5*120 | SM | 12.6 | 1.2 | 2.4 | 44 | 6157 | 526 | 30000 |
RE - Tus coj chav kawm 1 - puag ncig khoom;
RMV - Tus coj chav kawm 2 - puag ncig stranded compacted;
SM - Tus coj chav kawm 2 -sector-shaped stranded
Kev quab yuam yog muab faib rau tag nrho cov cable conductors;
Force rau rub lub taub hau los yog tus neeg xyuas pib tuav